.Air Monitoring in Lower Manhattan Page 3 of 3

DEP has been working with the involved City agencies, including the Board of Education, to provide air monitoring in and around the schpeds near the World Trade Center disaster site. DEP is collecting 8 hour ambient air samples that are analyzed for asbestos at four locations. These locations are outside of the main entrances to: Stuyvesant High School, IS/PS 89, PS 234 and the High School of Economics and Finance. DEP began sampling on October 4, 2001. From October 4th through October 18th, DEP only did a TEM analysis if the PCM concentration was above 0.01 fibers per cubic centimeter (f/cc). During this period of time, there was only one reading above 0.01 f/cc. The TEM result was below the Asbestos Hazard Emergency Response Act (AHERA) standard of 70 structures per square millimeter (s/sqmm). As of October 19, DEP began conducting a TEM analysis on all samples to provide a direct comparison to the AHERA standard. Of the 356 samples that have been collected between October 19 and January 15, 2002, all have been well below the AHERA standard of 70 s/sqmm. Since that period, the results continue to be well below the AHERA standard.

School Monitoring Data ►

Additonal Information

• Advisory for Building Facade Clean-up • Notice to Building Owners Located South of 14th Street, Manhattan: Building Maintenance Issues Involved in Reopening Buildings Closed Since 9/11/01 • New York City Department of Health Responds to the World Trade Center Disaster

Last updated February 1, 2002

Air. Noise and Hazardous Materials

• Air monitoring in Lower Manahattan • Certified Asbestos Investigators. Contractors and Firms • Asbestos Rules and Regulations (top) • Asbestos Abatement Activity Fonns

About DEP I Customer InformalionI Education Information IDEP News 1 Contact Us | DEP Homepage!

Go to NYC.gov Home Page Mayor's Office I City Agencies I ServicesI News and Features I City Life | Contact Us I Search

NYC-WTC_000150111

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000150111Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

Compare copies and versions →