28 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Law Department notice on WTC document preservation, Oct 2001
Machine-extracted title · confidence 95%Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
An experienced individual to act as a site health and safety supervisor to respond to unanticipated health hazards that may be encountered on the site and to ensure implementation of required health and safety practices.
6.2 In addition to the above minimum requirements, the duct cleaning professional shall meet the following contaminant-specific requirements:
6.2.1 Man-made Vitreous Fibers - appropriate Hazard Communication training and personal protective equipment 6.2.2 Crystalline Silica - appropriate Hazard Communication training and personal protective equipment 6.2.3 Lead - appropriate Hazard Communication training, ability to perform personal exposure monitoring for airborne lead, ability to comply with requirements of 29 CFR 1910.1025 6.2.4 Asbestos (< 1%) - - appropriate Hazard Communication training, ability to perform personal exposure monitoring for airborne asbestos, ability to comply with requirements of29 CFR 1910.1001
6.3 All workers shall possess current EPA-accredited training as an Asbestos Worker (32-hour training) or as an Asbestos Supervisor (40-hour training).
7.0 GENERAL PERFORMANCE REQUIREMENTS
In general, all cleaning of air moving equipment and active plenums shall be performed under negative pressure using HEPA-filtered air filtration devices. All ducts that are cleaned shall be maintained under negative pressure using HEPA-filtered vacuum collection equipment specific to the duct cleaning industiy. Air filtration devices and vacuum collection equipment shall be exhausted to the outdoors. After cleaning of the ventilation system, any areas that are affected by the work must be as clean or cleaner than their condition prior to the start of work, and must meet post-cleaning verification requirements contained in 8.2 of this document.
7.1 Containment: WTC-related dust and debris removed by cleaning/remediation process shall be collected and precautions taken to ensure that the debris is not otherwise dispersed outside the ventilation system during cleaning. After cleaning of the ventilation system, any areas that are aflTected by the work must be as clean or cleaner than their condition prior to the start of work.
7.1.1 When working outside the negative air pressure system the ventilation system/duct cleaning firm shall install plastic sheeting on the floor surface under and at a minimum of 3 feet outside the perimeter of the system. All exposed service tools and equipment shall be free of debris and contamination from the ventilation system. Tools and equipment include (but are not limited to): Vacuum collection equipment, vacuum hoses and attachments, air lines and hoses, brushes, extension rods, cables, ladders, power tools, hand tools, zoning devices, and inspection equipment.
7.1.1.2 Contaminated tools and equipment shall be maintained in poly bags until cleaned in the designated decontamination area at the work site.
5
NYC-WTC_000145209
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000140467
Contract section specifying minimum professional requirements and health safety protocols for individuals evaluating ventilation systems.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140292
Section detailing professional qualifications and health hazards like asbestos and lead encountered during World Trade Center ventilation evaluations.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163408
Second addendum to monitoring scope including HVAC system checklist and inspection procedures.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135765
City receiving report acknowledging delivery of HVAC consulting services for WTC from TAMS Consultants Inc.
Similarity score 0.954 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098612
Contract specifications outlining site decontamination and asbestos disposal procedures for 110 Church Street.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 5 pages · confidence 0.70 · verify page 179
- 170 William Street · 1 pages · confidence 0.00 · verify page 75
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer
NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer