NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 56/No folder label
Document / 186 pages

Receiving report for HVAC consulting services, March-April 2003

Machine-extracted title · confidence 94%

City receiving report acknowledging delivery of HVAC consulting services for WTC from TAMS Consultants Inc.

NYC-WTC_000135765–000135950
Page image
Scanned page image, NYC-WTC_000135785
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

16. Disengage the local capture system and relocate to another section of the duct to

be cleaned.

17. Prior to dismantling work area preparations, clean the interior walls of temporary containments using wet-wiping or HEPA _vacuum methods. The cleaning of work area preparations is a precautionary measure intended to minimize the potential for spreading dust or debris outside of the work area.

18. Occupied areas or common areas in which fan unit cleaning is accomplished, will be cleaned as common spaces using the common space unit prices, immediately after the HVAC cleaning is complete.

19. Place waste and debris into 6 mil polyethylene bags for disposal as asbestos-containing waste. Waste and debris from cleaning operations will be handled as asbestos-containing waste as a precaution.

20. Perform all duct cleaning work in accordance with local, state and federal regulations.

21. All work will be accomplished by DEP certified Asbestos Handlers.

22. All work will be supervised by a DEP certified Asbestos Handler Supervisor.

23. All work will be overseen by a NADCA certified ASCS or equivalent.

24. Workers will utilize /2 face APR's equipped with P-100 filters, eye protection and full body coveralls during the cleaning process.

25. In most cases minimal dust accumulations were observed on components and the system has been in operation for over a year, large amounts of debris are not expected during dismantling and cleaning of the system components. All specified cleaning is being performed after the installation of negative pressure ventilation equipment and system isolation devices. To date, none of personal air samples collected during the indoor dust cleaning program exceeded 0.1 f/cc asbestos. Based on past personal monitoring results which was conducted during Scope A and Scope B cleanings, previous residential monitoring, the condition of the systems to be cleaned and the required engineering controls which contain and move dust within the ventilation system thereby keeping it away from the workers breathing zone, it is reasonable to expect that personal air samples will not exceed 0.1 f/cc. Based on the above, the work area will not be considered as regulated area. The cleaning contractor shall collect personal air samples on workers and submit the results of sampling within 48 hours to establish personal exposure data for this work. If large accumulations of dust or debris are observed during the work or personal air samples exceed 0.1 f/cc work practices and engineering controls will be reevaluated and revised accordingly.

NYC-WTC 000135785

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135785Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117345 · Box DEP Box 46

January 30, 2003 letter from Athenica Environmental Services regarding HVAC and environmental inspections at 250 South End Avenue.

Similar indexed content

Compare copies and versions →