Unit 5D. Test: 3B- Industrial HEPA-filtered vacuum, AFD. Soap and water wet wipe of all
horizontal surfaces. This 1,024 sq. ft. open loft faces ground zero. All personal items removed
prior to cleaning. Windows blown in, hardwood floors, no carpet. Significant accumulation of
dust in dwelling.
Fifth Floor Hallway. Test: 4A- Industrial HEPA-filtered vacuum, AFD. Test: 4B- Soap and water
wet wipe of all horizontal and vertical surfaces (this hallway, ceiling only). Plywood floors, sheet
rock walls covered with wallpaper glue, painted sheet rock ceiling. Minimal dust accumulation.
Liberty Street Staircase. Test: 4A- Industrial HEPA-filtered vacuum, AFD. Test: 4B- Soap and
water wet wipe of all horizontal and vertical surfaces. Cast concrete steps/landings, sheet rock
walls and ceiling. All surfaces covered with gloss paint. Minimal dust accumulation.
Cedar Street Staircase. Test: 4A- Industrial HEPA-filtered vacuum, AFD. Test: 4B- Soap and
water wet wipe of all horizontal and vertical surfaces. Wood steps/landings, sheet rock walls and
ceiling. Floor covered with vinyl tiles, walls and ceilings covered with gloss paint. Minimal dust
accumulation.
Commercial Units
Chiropractor’s Office. Test: 4A- Industrial HEPA-filtered vacuums, AFD. Test: 4B-Soap and
water wet wipe of all horizontal and vertical surfaces. Test: 4C- Carpet cleaning using a
commercial carpet wet vacuum with warm water. Test: 4D- A/C Duct Cleaning. Test: 4E-
Cleaning of bathroom tile floor and desk top wet wipe using water only. This 716 sq. ft. office
space with 4 examination rooms faces ground zero. All front windows were blown in. Excessive
amounts of dust present on all horizontal and vertical surfaces. Floor areas covered with wall-to-
wall carpeting; suspended ceiling covered with fibrous tiles. A two foot high void space was
above ceiling. Ceiling tiles, flexible ventilation ducts and office equipment were removed and
disposed of prior to cleaning. Void space contained HVAC system, and wood floor joist system
for third floor apartment. This area contained WTC-related and non-WTC-related dust. The
space was extremely difficult to clean due to the present of electrical wires, recessed lighting
fixtures, sprinkler systems and the dry friable nature of the wood support system.
Mattress Store. Test: 4A- Industrial HEPA-filtered vacuums, AFD. Test: 4B-Soap and water wet
wipe of all horizontal and vertical surfaces. Test: 4C- Carpet cleaning using a commercial carpet
wet vacuum with a warm water shampoo solution. Test: 4D- A/C Duct Cleaning.
Test: 4E- Cleaning of vinyl floor tile and window ledge wet wipe using water only. This 968 sq.
ft. open space faces ground zero. All front windows blown in, excessive amounts of dust present
on all horizontal surfaces. Floor areas covered with wall-to-wall carpeting and approximately 25
display mattresses and box springs. Ceiling tiles, mattresses, office equipment and flexible
ventilation ducts removed and disposed of prior to cleanup. Void space above suspended ceiling
exhibited same characteristics as in the Chiropractor’s office.