outside is not possible, a second negative pressure ventilation unit compatible with the
primary unit capacity may be connected in series.
11. All debris shall be misled and bagged directly. Acciunulation of water is prohibited.
Water misting shall be sufficient to wet the material without water accumulations. After
the removal of debris accumulations all surfaces shall be HEPA vacuumed and then wet
wiped. An encapsulating agent shall not be applied. Once all surfaces have been wet
wiped, a second cleaning shall be performed. Surfaces include but are not limited to
walls, floors, ceilings, ledges, trims, appliances, and furnishings. The order of work shall
proceed as specified in Scope of Work A.
Surfaces that may not be wiped shall be HEPA vacuumed three times or disposed as
ACM waste. Disposal of material may not occur without prior authorization by the
building owner and/or space occupant as appropriate.
12. A thorough visual inspection shall verify the absence of visible dust accumulations.
13. After successful clearance air monitoring isolation barriers shall be removed in
conjunction with the use of a HEPA vacuum.
14. A log of activities and staff present shall be accurately maintained. The log shall include
entry and exit times from the unit. Sign in/out records for each individual who enters or
exits the unit shall be maintained. Activities performed within the unit shall be
documented at a minimum two-hour intervals. The results of inspections by the project
monitor and authorized agency representatives shall be entered in the log.
15. All work shall be in compliance with all other applicable requirements of Title 15,
Chapter 1 of the Rules of the City of New York and New York Industrial Code Rule 56.
Transportation and disposal of generated waste shall be in compliance with all applicable
rules and regulations.