b. The Monitoring Contractor will document all the necessary information regarding sampling
activities, fill out all field logs, data sheets, and chain-of-custody forms. The Monitoring
Contractor shall use F2L for all sample and chain-of-custody documentation. Samples
must be labeled and accompanied with completed chain-of-custody forms before shipping
to the designated laboratory. The label must include the EPA Project Tracking Number.
Samples will be packed, sealed and shipped daily by courier for next day delivery to
Paradigm Analytical Laboratories at: 2627 Northchase Parkway SE, WilmingtonNC
28405
Deliverables
The Project Monitor shall complete chain-of-custody forms and record the number of wipe
samples, EPA Project Tracking Numbers, the laboratory address, date, and sample IDs in an
agreed upon electronic format or website approved by EPA within 24 hours of activity.
9. The Project Monitor shall schedule and oversee the cleaning operations ofthe Cleaning Contractor.
No residential, common space or HVAC system shall be cleaned until the exterior ofthe building
has been cleaned or has been inspected and found to be free of dust or debris form the collapse
ofthe WTC. No residential or common space shall be cleaned until the HVAC systemhasbeen
evaluated and cleaned as necessary. Ifa scheduling problem arises the Proj ect Monitor should
contact EPA. The Project Monitor shall coordinate daily access for cleaning and sampling with
residents, owners, the Cleaning Contractor and sampling technicians.
10. The Monitoring Contractor shall provide sufficient personnel to provide periodic (3-4hours/unit)
oversight ofthe Cleaning Contractor to verify that work is being conducted in accordance with the
Cleaning Contact Scope of Work.
11. The Project Monitor shall verify that the Cleaning Contractor is using properly trained and certified
NYSDOL and NYCDEP Certified workers.
12. The Project Monitor shall conduct routine quality assurance inspections during the course of
cleaning and concurby initialing the Cleaning Checklist (to be developed) fortasks completed in
compliance with the Cleaning Contract Scope of Work.
Deliverables
The Project Monitor shall submit the completed Cleaning Checklist via F2L or an agreed upon
alternative electronic format or website approved by EPA within 24 hours of activity.
13. Personal Air Monitoring
Personal air monitoring shall be performed by the Monitoring Contractor in accordance with
9
NYC-WTC_000139218