DEP Biweekly Reports Folder 0049, 2000-2001

Machine-extracted title · confidence 100%

Archival folder label for Department of Environmental Protection biweekly reports related to World Trade Center activities from 2000 to 2001.

NYC-WTC_000137900–000137982

Folder label: “Folder_0049

Page image
Scanned page image, NYC-WTC_000137927
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Local Law 65/96 Notifications and Notices of Violations (NON); Ciywtde In order to insure that septic systems have been properly abandoned, field inspectors from DEP are requesting that plumbing contractors supply DEP with copies of their receipts from the septic clean- out and backfill subcontractor.

DEP Policyfor Multiple Family Residences; Citywide DEP is reviewing issues related to policy regarding multiple premises which are served by one (1) water service line. Present DEP polity allows for one (1) domestic water service line per building,

Certifrcater of Occupancyfor DEP Facilities; Citywide DEP is exploring the best methods to obtain Certificates of Occupancy ( C of 0) for DEP facilities. A check of records indicates that a number of DEP facilities completed within the past 40 to 50 years lack C of O's, unless they have been recently renovated or upgraded. We are committed to obtaining C of O's for all facilities.

Force Main Leak at Red Hook Plant Last week, evidence of leakage was discovered coming frem a 66-inch force main connecting one of the main sewage pumps and the primary tanks at the Red Hook WPCP. A repair contractor was called in, and after excavation work was completed, it was discovered that there was leakage from two separate holes in the casing, as well as a small crack. The contractor's first attempt at repairs was an application of epoxy to the problem points, but leaking continued. The contractor is now in the process of fabricating a unique band clamp that will encircle the entire force main, after which the steel casing portion of the pipe will be encased in While the plant awaits these final concrete.

repairs, a temporary sump pump has been installed to reduce the flow in the force main, keeping leakage to a minimum. The swift action by plant personnel in initiating the repair process has prevented a major failure of the force main, along with its potential for significant disruption of plant operations.

International Videoconference/September 26th and 27th DEP staff in New York City contributed to an exchange with a conference on trenchless technology being held in Paris by formal presentations of New York City's perspective on trenchless technology and on our plans for continuous electronic monitoring of large trunk watermains, Staff from DDC and private utilities also participated.

Westchester Waterworks DEP Water Supply staff attended an opening of the new water treatment facility for Northern Westchester Joint Water Works on September 29th.

Recognition of DEP Employee On September 21st the Concrete Industry Board presented an award to George Cakiades of DEP. George has many years of public service beginning with the board of wafer supply continuing with its successor DEP. The award was in recognition of his many years of commitment to assuring concrete quality on various DEP projects.

-9-

60'd Ob:St OOOL Z MoD SLS2 S6S 8IL:Xei d3Q NYC-WTC 000137927

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000137927Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Cited alongside this record in an Ask answer

Compare copies and versions →