NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/Unboxed/Folder_0048
Document / 151 pages

DEP Environmental Protection Invoices, 1999-2001

Machine-extracted title · confidence 100%

Archival folder label for Department of Environmental Protection invoices related to World Trade Center activities from 1999 to 2001.

NYC-WTC_000137749–000137899

Folder label: “Folder_0048

Page image
Scanned page image, NYC-WTC_000137778
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 1U / FJUL ♦o;_4 DIU'- - _J VNOt b4/tl~

A. Limnological monitoring will be performed at sites 3.1, 4, 4.1, 4.2 and 5 on days 1, 2, 3, 5, 7 and 9 and then three times per week as proposed in the attachments to Mr. Hoffer's January 8, 2001 letter to Ms. Duke of NYSDEC. Any changes in alum and sodium hydroxide dose or treatment regime (e.g. increase in alum and sodium hydroxide dose) due to increases in turbidity should result in increased monitoring (i.e. revert to daily sampling until stable turbidity removals are achieved). The City must make every effort to sample these sites, regardless of ice cover conditions.

B. The sediment traps deployed at Sites 5, 4.2, 4.1 and 4 during the addition of alum and sodium hydroxide to the Catskill System must be collected every week.

C. Pathogen samples (Giardia spp. and Cryptosporidium spp.) must be collected daily at the two Kensico effluent keypoint locations (DEL 18 & CATLEFF) throughout the duration of the alum and sodium hydroxide application, unless a reduction is authorized by this Office;

5. keypoint and Limnological monitoring results are to be submitted to this Office as the data become available. Pathogen data are to be transmitted within one week from the sample date;

6. the City must demonstrate that every effort is being made to reduce unnecessary or excessive water use within the City's distribution system;

the City must accelerate the repair/remediation efforts currently underway in the Southern portion of the New Croton Aqueduct. Every possible effort should be made to expeditiously get the Croton system back on line;

8. the City must maximize the use of the Delaware and Croton systems during this alum and sodium hydroxide treatment event; and

9. the DEP must notify this office when the alum and sodium hydroxide operation is terminated and prepare and submit an After Action Report within 60 days of the end of the alum and sodium hydroxide operation.

Sincerely,

Michael E. Burke, P.E. Director Bureau of Public Water Supply Protection

NYC-WTC 000137778

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000137778Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000137900

Archival folder label for Department of Environmental Protection biweekly reports related to World Trade Center activities from 2000 to 2001.

Cited alongside this record in an Ask answer

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.