Part II - Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701— Rev 2 September 16, 2005
Metals sampling and analysis will be performed following NIOSH 7300 "Elements by
ICP," except that ICP-MS will be utilized. A hot blocklacid digestion will be utilized.
Metals to be analyzed by ICP-MS and reported are: Antimony, Barium, Beryllium,
Cadmium, Chromium, Copper, Lead, Manganese, Mercury (particulate), Nickel and
Zinc.
Total Dust sampling and analyses will be conducted by NIOSH 0500.
Mercury:
In addition to metals monitoring for mercury particulate using air filters, real-time
monitoring will be performed. The readings will be entered into the PDA program for
inclusion with the daily download of sample collection data.
Real-time monitoring will be performed daily throughout the project. Mercury
monitoring will be performed utilizing a Lumex RA 915+ direct read instrument.
The Lumex RA915+ will be utilized to obtain detection levels below established Site air
contaminant criteria. At a minimum, mercury readings will be taken twice a shift at the
fixed air monitoring locations. At the discretion of the Environmental Consultant and as
daily Site conditions may dictate, additional mercury readings may be taken.
Organic Compounds (Dioxin/PCBs/PAHs):
Organic compounds samples will be collected at specified points along the project
schedule as follows:
1. On the first day of the Background Phase, one sample of each organic
compound at each community monitoring location will be collected (three
total samples per location). The samples from the location with the highest
particulate readings will be analyzed.
2. Organic samples will be collected at each community monitoring location
once a week on a different day of the work week during the Abatement Phase
and Demolition Phase, until all days of the work week are used and then the
same schedule will be repeated until project completion. Samples from the
location with the highest particulate readings for that day will be submitted for
analysis. This will result in the processing of the samples that have the best
likelihood of representing the "worst case." A total of three samples per week,
one Dioxin, one PCB, one PAH will be analyzed.
3. Samples for organic compound analyses will be analyzed within fourteen days
under normal laboratory analysis turn-around time