NYC-WTC_000099219
Letter to DEP listing potential contamination questions regarding WTC debris cleanup at 93 Nassau Street.
5 shared non-person entities · 1 shared topics · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗Specifications document for lead-based paint removal at the 130 Cedar Street site.
NYC-WTC_000125675–000125696Folder label: “130 CEDAR STREET”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Lead Based Paint Removal Technical Specifications For 130 Cedar Street New York, NY 10006 contain all water runoff.
IN E. Hand Washing:
1. Hand washing facilities shall be made available to all workers.
3.02 EXECUTION
1. All work must be performed in accordance with Occupational Safety and Health Administration (OSHA) 29 Code of Federal Regulation (CFR) Part 1926.62, and all applicable local, state and federal regulations.
2. At the end of the demolition project, have a certified inspector technician or risk assessor conduct a clearance examination and provide appropriate documentation or statements of lead-based paint compliance.
3.03 WORK AREA CLEAN-UP
A. Clean-up procedures shall utilize HEPA-filtered vacuum systems and/or wet methods, such as mopping, wet wiping, shoveling of wet debris, etc. No dry sweeping of dust, particulate matter or debris is allowed during any phase of the work affecting lead-coated surfaces. Cleaned surfaces must meet HUD EPA reoccupancy standard for lead in dust.
• 3.04 DISPOSAL: Disposal of Non-hazardous construction and demolition debris.
A. The Contractor shall conduct the Mass Balance TCLP Testing for lead to categorize the proposed waste strewn prior to initiation of work. If the test results indicate that the waste strewn meets the requirements for disposal as non-hazardous construction and demolition debris the contractor will be provided with the necessary documentation for disposal.
3.05 DISPOSAL: Disposal of hazardous waste.
A. The Contractor shall conduct TCLP testing of all waste generated during the demolition of components coated with detectable levels of lead.
B. All waste shall be kept drummed, secured, labeled and stored in a designated secured storage space on site until test results categorize all waste to be hazardous or non-hazardous.
C. The lead based waste media or other debris must be stored in a manner that will not allow entry of any hazardous material into the environment. Leak-proof drums or portable bins, such as gondolas, are generally acceptable. The lids of the drums, or the covers of the bins, must be firmly secured. The containers must be kept out of flood plains or areas where run-off may occur. Weather resistant labels using indelible ink warning of the potential hazards associated with the material must be place on the containers. The containers should be • marked with the contents, tare weights of the containers, and the origin and date of collection of the material. The containers must be keyed to the samples taken. Prepared by JLC Environmental Consultants, Inc. Project No. 04-3271 02085-15
NYC-WTC 000125691
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000099219
Letter to DEP listing potential contamination questions regarding WTC debris cleanup at 93 Nassau Street.
5 shared non-person entities · 1 shared topics · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
7 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096827
Document identified only by its archive reference number with no visible text content in the excerpt.
6 shared non-person entities · 1 shared topics · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗7 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
11 shared non-person entities · 1 shared topics · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096888
Resident request form authorizing DEP to perform cleaning and monitoring work at a Manhattan residence following the attacks.
2 shared non-person entities · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098577
Contract specifications outlining site decontamination and asbestos disposal procedures for 53 Park Place.
9 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000101360
Automated fax transmission log record dated March 10, 2003 showing successful transmission to NYC DEP.
6 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098612
Contract specifications outlining site decontamination and asbestos disposal procedures for 110 Church Street.
9 shared non-person entities · similarity 0.906
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107169
Letter from DEP responding to an inquiry by enclosing scopes of work for environmental cleanup at 125 Cedar Street.
8 shared non-person entities · similarity 0.906
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000095834
Part IV of a permit application dated January 10, 2006 detailing the remediation and management plan for 30 West Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096519
Cover page for a remediation and deconstruction plan prepared for the State of New York.
Cited alongside this record in an Ask answer
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000144916
Large volume technical report containing environmental data and analysis related to the World Trade Center disaster site cleanup.
Cited alongside this record in an Ask answer