NYC 9/11 Public Portal Document
JLC Environmental Consultants, Inc.
200 Park Ave. Swath - Suite 1001. New York, NY 1001.3
Phone: (212) 420-8119 - Fax: (212) 420-6092
Project No: 04-3271
Masterworks Development Corp. ELAP Lab Code: 11029
Analyte: ASBESTOS
56 West 45th Street NIOSH and AIHA Lab Code: 100273
Date Received: 05/27/2004
New York NY 10036 NVLAP Lab Code: 101953-0
Da Analyzed: 05/27/2004
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0403452
SITE: 130 Cedar Street
SAMPLE #
Asbestos Non-Asbestos
COLLECTED DESCRIPTION / LOCATION COLOR Asbestos Constituents Constituents
LAB # Detected? (%) (%)
*Insufficient material submitted **TEM recommended ***Not analyzed positive stop
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS)
Method of Sanmle Pmnaration and Analysis:
All samples were prepared and analyzed in accordance with the EPA "Method for the Determination of Asbestos in
Bulk Building Materials" USEPA/ 600/R-93/116, July, 1993
Instrumehntation:
Olympus Pill, Model BH-2/VM stereotnicroscope Model VMZ 1x-4x.
Analytical results reflect the nuke up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except
in full, without the written approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the
• U.S. Government. This method is not applicable to samples containing large amounts of fine fibers below the resolution of the light microscope. The
value of this method is limited to the quantitative identification of asbestos and the semi-quantitative determination of asbestos content of bulk samples,
expressed as a percentage of the projected area. Quantitation of asbestos content was determined with a visual volume estimate, a calibrated visual
area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences
and will be considered asbestos under this methodology. Also, PI.M is not consistently reliable in detecting asbestos in floor coverings and similar
non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine
if this material can be considered or treated as non-asbestos containing.
• _______
Gulam Machh iwala, Lab Director
Page 8 of 8 Report Date: July 06, 2004
NYC-WTC 000125325
OCR can misread numbers and units. Confirm readings against the page image before using them.