JLC Environmental Consultants, Inc. 200 Park Ave. South - Suite 1001. New York, NY 10013 Phone: (212) 420-8119 - Fax: (212) 420-6092 Masterworks Development roject No: 04-3271 oP Corp. ~P• FLAP Lab Code: 11029 56 West 45th Street NIOSH and AIHA Lab Code: 100273 Analyte: ASBESTOS

New York NY 10036 Date Received: 03/24/2004 NVLAP Lab Code: 101953-0 Date Analyzed: 03/25/2004 SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0403103 SITE: 130 Cedar Street #Deleted

SAMPLE # COLLECTED Asbestos Non-Asbestos DESCRIPTION/ LOCATION COLOR Asbestos Constituents Constituents LAB # Detected? (%) (o/n)

17H 2x4 Corrugated Pipe Insulation, Brown, Brown Yes Chrysotile 50% Cellulose Fiber Est. 50% 03/23/2004 Homogeneous, Friable 0403103-017 Basement/ South Section/ East/ Middle! Sample of 2x4 Corrugated Pipe Insulation

18H 2x4 Corrupted Pipe Insulation, Brown, Brown 03/23/2004 Friable Note: Not Analyzed 0403103-018 Basement/ Electric Rooni1 East/ Middle/ Sample of 2x4 Corrugated Pipe Insulation

0 191 03/23/2004 l Ox12 Elbow Insulation, Tan, Homogeneous, Friable Tan Yes Chrysotile 30.8% Cellulose Fiber 2.2% 0403103-019 Basement/ South Section/ But Wall/ Non-Fibrous Material 67% Middle! Sample of Wall Plaster

201 10x12 Elbow Insulation, Tan, Friable Tan 03/23/2004 Note: Not Analyzed 0403103-020 Basement/ South Section/ East Wall! Middle/ Sample of Wall Plaster

21I 10xl2 Elbow Insulation, Tan, Friable Tan 03/23/2004 Note: Not Analyzed 0403103-021 Basement( South Section/ West! On North/ Sample of 10x12 Elbow Insulation

22J 10x12 Corrugated Pipe Insulation, Tan, Tan Yes Chrysotile 50% Cellulose Fiber 50% 03/23/2004 Homogeneous, Friable 0403103-022 Basement/ South Section/ East/ South Side/ 10x12 Corrugated Pipe Insulation

Gulam Machhiwala, Lab Director Page 4 of 25 Report Date: July 06, 2004

NYC-WTC 000125258

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125258Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →