Air sampling protocol document, 130 Cedar Street, Jan 2005

Machine-extracted title · confidence 100%

Protocol document outlining air sampling and monitoring procedures for 130 Cedar Street.

NYC-WTC_000125098–000125202

Folder label: “130 CEDAR STREET

Page image
Scanned page image, NYC-WTC_000125104
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

• Air Sampling and Monitoring Protocol Site: 130 Cedar Street Prepared for Masterworks Development .45-micron mixed cellulose ester (MCE) membrane 25mm in diameter with a conductive cowl on a cassette. Sample volumes will various due to various site- specific conditions.

4) Silica Sampling: Silica samples will be collected according to NIOSH 7500 Method using XRD analysis.

5) Fibrous ekass Sampling: Fibrous Glass samples will be collected according to .NIOSH 7+400 ethod using counting method "B".

6) Dioxin/Furan Wipe Sampling: D/F samples will be collected according to ASTM method 6661-01 and analyzed by EPA Method SW-846-8290.

7) Poly Cyclic Aromatic Hydrocarbon Sampling: PAH samples will be collected using ASTM method D6661-01 and analyzed using EPA method SW-846-8270C.

8) RCRA Metals Sampling: RCRA metals samples will be collected using wipe samples pre-moistened with de-ionized water.

9) Mercury will be sampled Utilizing EPA modified method7471A.

10) Poly chlorinated bi Phenols will be sampled utilizing EPA modified method 8082.

4.0 Quality Assurance and Quality Control

Quality Assurance (QA) includes the systematic actions necessary to provide adequate confidence that a measurement will satisfy a given requirement for accuracy. Quality Control (QC) is the operation techniques that are used to fulfill requirements for quality. The QC procedures for the air sampling and monitoring sections of this protocol include planned equipment calibrations, preventative maintenance of equipment, co-located sampling to evaluate precision and analysis of QC samples consisting of field blanks and lab blanks.

5.0 ,,Alarm and Action Levels

Thegoal of the air sampling ' and monitoring protocol is to ensure the Ilk deconstruction operations at the subject property do not have a negative impact on the airborne environment of the surrounding community. Any action and alarm levels that may be established and utilized for the COPC would be solely for that. purpose rather than providing compliance with any known health standard.

t

NYC-WTC 000125104

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125104Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →