AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS/IS89M. Page 7 of 8

PCB WIPE SAMPLES

• First floor hallway, near north entrance - one sample. • First floor hallway, near south entrance - one sample. • Second floor hallway, near staircase - one sample.

All sample collected shall be analyzed utilizing the EPA 8081 method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

HEAVY METAL AIR SAMPLES

• First floor hallway, outside cafeteria - one sample. • Inside playground, north side - one sample. • Inside playground south side - one sample. • Fifth floor roof - one sample.

All sample collected shall be analyzed utilizing NIOSH 7300 method for Al, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Ni, Zn and NIOSH 6009 method for Hg.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

TVOCs AIR SAMPLES

• First floor hallway, outside cafeteria - one sample. • Inside playground, north side - one sample. • Inside playground south side - one sample. • Fifth floor roof - one sample.

All sample collected shall be analyzed utilizing Hydrocarbon Scan (16+A&B) OSHA 7 method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

CITY_21MC100_0 09363869

NYC-WTC_000234657

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000234657Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000153247 · Box DEP Box 26

Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.

Similar indexed content

Compare copies and versions →