130 Cedar Street July 15, 2004 Selective Demolition and Façade Restoration Koenen Associates

compliance shall be performed by the same testing laboratory and inspectors and the costs thereof will be deducted by the Owner from the Contract Sum. 0 2.02 CODE COMPLIANCE TESTING AND INSPECTION

A. Inspections and tests required by all applicable Codes or Ordinances shall be paid by for by the Owner unless otherwise noted in this Section or other Sections of work. Retesting or inspection as required shall conform to the requirements of Article 2.01B of this Section.

2.03 CONTRACTOR'S TESTING

A. Inspection or testing performed exclusively for the Contractor's convenience shall be the sole responsibility of the Contractor.

B. Where operating tests are specified, the Contractor shall test his work as it progresses, on his own account, and shall make satisfactory preliminary tests in all cases before applying for official tests.

C. Tests shall be made in the manner specified, for the different branches of the work. Each test shall be made on the entire system for which such test Is required, wherever practical. In case it is necessary to test portions of the work independently, the Contractor shall do so without extra compensation. The Contractor shall furnish all labor, material and apparatus, make connections and conduct the official test. The test will be conducted In the presence of a representative of the Architect.

D. All parts of the mechanical and electrical work and associated equipment shall be tested and adjusted to work properly and be left in perfect operating condition. All defects disclosed by these tests shall be corrected to the satisfaction of the Architect and Engineer without any additional cost to the Owner. Tests shall be repeated on this repaired or replaced work if deemed necessary by the Architect. The Architect shall be notified at least forty-eight (48) hours in advance of all tests, and shall be represented at tests that he deems necessary. The Contractor shall furnish all necessary instruments, other equipment, and personnel required for such tests.

E. Required certificates of inspection, testing or approval shall be secured by the contractor and promptly delivered by him to the Architect.

F. If the Architect or Engineer is to observe the inspections, test or approvals required by the Contract Documents, he will endeavor to do so promptly and, where practicable, at the source of supply.

PART 3.00 - EXECUTION

3.01 COOPERATION WITH TESTING LABORATORY AND INSPECTORS

A. Representatives of the testing laboratory and inspections shall have access to the work at all times. Provide facilities for such access in order that they may properly perform their functions.

3.02 SCHEDULES

A. Establishing Schedule

Testing and Inspection 01400-2

NYC-WTC 000125128

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125128Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →