NYC 9/11 Public Portal Document Nvl; utN AUF hax:7185953648 Feb 28 2005 17:06 P.07 9

EAT.cOAS'r HAZ MAC OVAl4,INC Asbestos Abatement Contractor -494•E.41 Street, Paterson, NJ 07504 Phone:(973)345-0022 fa±(973)3145:4665

Date:January 20, 2005

Mr. Rajappan Radhalrishnan, Acting Director NYC Department of Environmental Protection Bureau of Air, Noise and Hazardous Materials Asbestos and Lead Control Program .59-17 Junction Boulevard -8th Floor Elmhurst, NY' 11373

RE: Petition for variance: 130 Cedar Street, NY 10460 Corrected.

Dear Mr. Radhalocishnam.

In lieu of the necessary building renovation and site conditions at this site, it is necessary to perform asbestos abatement procedures before any renovation.activities can take place. Our petition for variance involves roofing/flashing/tar, VAT/mastic, pipe insulation, ceiling/wall/columns slam coat plaster, boiler insulation, transite panels, windows/lintels caulking, fire doors and electrical wires.

Reason for Requesting a Variance Petition Due to the fact that there are practical difficulties in constructing a full containment and the large quantities which exist at this site as required by regulations, East Coast Haz Mat Removal, Inc. is requesting the following variances from Title 15 Chapter 1 of the Rules of the City of New York:

L Work Area: Roof

TABLE OF SPECTFTC T.nCATTnNC flF 1QAAV ARA'IW=Vlr FLOOR SECTION OF AFFECTED AMOUNT DESCRIPTION OF FLOOR SURFACES OF ACM WORK Main Roof Entire Roof Roof Membrane Top 4500 SF Variance FR & R Main Roof Entire Roof Perimeter Flashing Tar 1200 SF Variance FR & R Main Roof Entire•Roof Tar Paper over Plywood .684 SF Variance FR & R Total 6384 Bulkhead Exterior Elevation Bulkhead Tar 6000 SF Variance FR &R Bulkhead Exterior Elevation Bulkhead Plashing Tar 200 SF Variance FR &R Total 6200 SP' Water Tower Entire Roof Roofing Membrane 800 SF Variance PR & R Water Tower Entire Roof Perimeter Flashing 270 SF Variance FR & R Water Tower Entire Roof Tar Material 20 SF Variance FR & R Total 1090 SF

1•

NYC-WTC 000125082

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125082Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →