May 10, 2002
Mr. Walter Symanski
Cushman & Wakefield
99 Church Street
New York, New York 10005
RE: Confirmatory Asbestos Bulk Sampling of debris from the Various Roofs
99 Church Street
Dear Mr. Symanski:
ATC Associates Inc. (ATC) has been retained by Cushman & Wakefield to perform bulk sampling and
analysis at the above referenced project site. Confirmatory sampling, following ATC's detailed sampling
conducted on February 19, 2002 as referenced in our April 8, 2002 correspondence, was conducted on May
8, 2002. ATC collected an additional three (3) samples in total from the 12th and 13th floor roofs and
subjected them to the more definitive Transmission Electron Microscopy (TEM) method for determining
asbestos in material as opposed to the optical Polarized Light Microscopy (PLM) method.
The extreme pressures and forces generated by the collapse of the World Trade Center buildings, forced the
reduction of the asbestos to an extremely small fiber size. As a result, these fibers may go undetected under the
standard optical PLM method. Under these circumstances, ATC's laboratory conducted additional bulk sample
analysis via Transmission Electron Microscopy (TEM), which is a state-of-the-art methodology for a more
definitive analysis whenever PLM results are negative or inconclusive. The results of this round of TEM
analysis clearly shows that either less than one percent of asbestos, or no asbestos were detected in each of the
analyzed samples. Therefore, the debris located on the roof levels of 99 Church Street is not asbestos
containing and warrants no further action.
ATC's laboratory is accredited by the New York State Department of Health (ELAP No.10879) and the
National Voluntary Laboratory Accreditation Program (NVLAP No. 101187).
Attached are the typewritten bulk sample results, including TEM results for this round of bulk testing.
Should you have any questions or require additional information, please do not hesitate to call.
Sincerely,
ATC ASSOCIATES INC.
Benjamin M. Sallemi
Senior Project Manager