NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 50/99 CHURCH STREET Block: 123 Lot: 10 BIN: 1001396 26/42 PARK PL, 23-41 BARCLAY ST
Document / 58 pages

Asbestos bulk sampling lab report, 99 Church Street, May 2002

Machine-extracted title · confidence 95%

Laboratory results for confirmatory asbestos bulk sampling conducted on the roofs of 99 Church Street in May 2002.

NYC-WTC_000124246–000124303

Folder label: “99 CHURCH STREET Block: 123 Lot: 10 BIN: 1001396 26/42 PARK PL, 23-41 BARCLAY ST

Page image
Scanned page image, NYC-WTC_000124253
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th Street New York. New York 10010

TC www.atc-enviro.com v

212.353.8280 Fax 212.353.8306

A S S O C I ATES I N C.

September 27, 2001 VIA FACSIMILE: 212-635-0872

Mr. Joe Freda Cushman & Wakefield, Inc. 99 Church Street New York, New York 10007 Re: 99 Church Street, New York, New York World Trade Center Emergency Response

Dear Mr. Freda, emergency clean up at the above ATC Associates Inc. (ATC) has been retained to respond for and subjected them to referenced site. ATC collected bulk samples of interior dust accumulations analysis documents that Polarized Light Microscopy (PLM) analysis on September 18, 2001. The show that trace amounts (<1%) of the dust was not asbestos containing. However, the results did asbestos was present, therefore, as a precaution, the bulk clean up was performed by a licensed asbestos abatement contractor, Pinnacle Environmental Corp. visual inspections and collected ATC observed daily cleaning activities, performed the required Analytical results showed airborne fiber air samples within the building following the clean up. 0.01 fibers per cubic concentration within the building to be less than the regulatory standard of analysis at the time of centimeter of air (<0.01 f/cc) by Phase Contrast Microscopy (PCM) air monitoring results it is testing. Based upon ATC's observation of work and the satisfactory compliance with applicable ATC's opinion that the work was performed in substantial regulations and that the abatement area meets the regulatory criteria for re-occupancy. herein is based on the physical ATC Associates Inc. certifies the information contained the work. All areas inspections conducted by ATC and the air sample data collected during were cleared for reoccupancy by PCM. of the information presented please If you have any questions or require additional explaination do not hesitate to call me at 212-353-8280 Sincerely,

gJM&. Benjamin M. Sallemi Senior Project Manager ATC Associates Inc.

Cc: M. Rocco Via Fascimile 413-513-2356

\1 NYC-WTC 000124253

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000124253Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →