JUN-17-2002 02:00P FROM: TO:12122360041 P:2'14

KAM CONSULTANTS 35.40 36thStreet Long IslandCity New York,11106 Tel:(118)729-1997 Fax:(718)729.1816

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 222 Broadway, Manhattan - 29th,24th,23rd,22nd,20th,18th,16th,l5th Floors PROJECT#: Client Sample ID# : 01-29 02-29 03-24 04-23 05-22 Lab Sample ID#: 020514A-1278 020514A-1279 020514A-1280 020514A-1281 020514A-1282 Sample Location: 29th Floor Cooling 29th Floor Cooling 24th Floor Center 23rl Floor S/West 22nd Floor West Tower N/East Tower S/East on Set Back Comer Set Back Comer Set Back Corner Flashing Corner Flashing Roof Flashing Roof Flashing Roof Flashing

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Wipe Wipe Wipe Wipe Wipe

Color: WhBrn Wh Wh Wh/Gr Gr/Wh Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): <l%FBGL <1%SYNTH l%SYNTH 1%CELL <1%CELL 5%SYNTH Non Fibr. Mat. (Percent): 94% >99% 99% 99% >99% Date Received: 5/14/02 Date of Analysis: 5/14/02 Date of Report: 5/15/02

Analyst: . Lab Manager: Roo Louis David Chen • Analysis of samples is performed Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) • Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) • PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request • The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYSDOH SLAP # 11273 NIST-NYLAP # 102047 AIHA #: 100269

Page 1 of 2

NYC-WTC 000105912

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105912Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →