BULK SAMPLE ANALYSIS REPORT
CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768
BUILDING ADDRESS: 222 Broadway, Manhattan - 29th,24th,23rd,22nd,20th,18th,16th,l5th Floors
PROJECT#:
Client Sample ID# : 01-29 02-29 03-24 04-23 05-22
Lab Sample ID#: 020514A-1278 020514A-1279 020514A-1280 020514A-1281 020514A-1282
Sample Location: 29th Floor Cooling 29th Floor Cooling 24th Floor Center 23rl Floor S/West 22nd Floor West
Tower N/East Tower S/East on Set Back Comer Set Back Comer Set Back
Corner Flashing Corner Flashing Roof Flashing Roof Flashing Roof Flashing
Homogeneity: Yes Yes Yes Yes Yes
Sample Description: Wipe Wipe Wipe Wipe Wipe
Color: WhBrn Wh Wh Wh/Gr Gr/Wh
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent): <l%FBGL <1%SYNTH l%SYNTH 1%CELL <1%CELL
5%SYNTH
Non Fibr. Mat.
(Percent): 94% >99% 99% 99% >99%
Date Received: 5/14/02
Date of Analysis: 5/14/02
Date of Report: 5/15/02
Analyst: . Lab Manager:
Roo Louis David Chen
• Analysis of samples is performed Polarized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
• Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
• PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
• The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
NYSDOH SLAP # 11273 NIST-NYLAP # 102047 AIHA #: 100269