Air quality test reports cover letter, Jan 2002

Machine-extracted title · confidence 90%

Cover letter enclosing air and bulk sampling results for 86 Trinity Place, 22 Thames, and 65 Broadway.

NYC-WTC_000105069–000105153

Folder label: “125 GREENWICH STREET Block: 51 Lot: 14 BIN: 1001034 18-22 Thomas Street, 129 Greenwich St

Page image
Scanned page image, NYC-WTC_000105074
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Papoo AMEX Air Quality, 31 January, 2002

All asbestos air samples were all less than detectable limits. See attached tables, TEM Air Sample Results.

No asbestos bulk samples were collected because no bulk amounts of dust were visible on surfaces in the restaurant area. Bulk samples are considered asbestos containing material when they contain more than one percent asbestos.

The respirable dust (breathable) in air samples were collected from areas considered representative of the space. Respirable dust samples were collected and analyzed to show particle dust mass and the distribution of particle size. The particulate dust mass shows the quantity of particulate in the air. The particulate size distribution shows the size of the particulate in the dust collected. Particles less than 10 micrometers (10 jim) can be inhaled by the lungs. Particles less than 5 micrometers (5 µm) can be inhaled deep into the alveoli of the lungs. The respirable dust mass and the distribution of particle size in air results are presented in the tables below.

Papoo AMEX, Respirable Dust Mass and Particle Size Distribution in Air Results, 31 January 2002 Location Air Volume Results ig/m3 1-5jum 6-10km >10Mm Liters particulate particulate particulate counted counted counted Bar - Entrance 552 230 7 22 213 Access through Bar 649 250 11 27 303 Dining - window 635 < 0.1 4 16 254 Kitchen 739 < 0.1 3 8 0 Basement 1008 <0.1 2 0 0

The respirable dust mass and size distribution results indicate that the air in the restaurant at the Bar - Entrance, and Access has significant levels of dust. The EPA National Ambient Air Quality Standard for PM 10 is 50 /cg/m3. The other areas of the restaurant have negligible dust levels.

The lead in air samples were collected from areas considered representative of the space. The lead in air results are presented in the table below. Papoo AMEX Lead in Air Results, 31 January 2002 Location Air Volume Liters Results µg/m'

Bar 1,104 < 1.0

Kitchen- dining room 1,153 < 1.0

The results are all less than detectable limits. The EPA National Ambient Air Quality Standard for lead is 1.5 µg/m3. These results met the U.S. EPA National Ambient Air Quality Standard for lead and are considered safe for reoccupancy.

Polynuclear aromatic hydrocarbons (PAHs) were collected because PAHs are produced through

Page 2 of 5

NYC-WTC 000105074

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105074Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →