NYC 9/11 Public Portal Document
j)AH,Y 1Pt I XJ1LON
INDI L6
I ()
()
<)
()
All isolation barriers, and polyethylene intact.
Decon clean and intact, all posted materials in place.
-.
° () Proper wet methods employed, no large piles of debris.
'' ()
() All personal protective equipment in use.
(} () Negative air filtration unit and shower filters in place.
() () - Licensed supervisor on site.
1 0
(}
()
(}
Workers licensed, licenses and names recorded.
OSHA monitoring preformed. .
() () Negative air filtration hose (snakes) intact.
t} (} Water off and shower pan emptied at cad of day's abatement.:
I C) 0 Negative air filtration units nu niag24hours per day e.g. left running at
cad of day and foundrmmiag at the beginning of the day.
C} (} Workers followingProper'catering end exitpcooedur
U () Sufficient equipment available,.
C} (} All waste double bagged and wetted prior to waste load out.
(} () Conventional waste dcoontaminated before waste load out.
(} (} Copies of waste transport tickets supplied to miilmaua representative.
C} C} Negative air pressure maintained readings.
() C} Air.sampling taken of adjacent areas, clean room, HEPA exhaust
C} (} Corrective action taken if any air tests above 0.01 fl'cx and the
preabatement base line readings.
I ' Pass Raft ()
I
NO space is checked of Please explain the re 1son.
L is (unusual events, etc.):
I
I
NYC-WTC 000104964