NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Facsimile cover sheet transmitting documents regarding environmental work at 102 Greenwich Street.
NYC-WTC_000104853–000104885Folder label: “102 GREENWICH STREET Block: 53 Lot: 37 BIN:1001054 104 Greenwich Street”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
N
C. DECONTAMINATION PROCEDURES
1. The contractor shall provide an adequate decontamination unit consisting of a serial arrangement of rooms or spaces adjoining the work area or a decontamination trailer. Each airlock shall be clearly identified and separated from the other by three polyethylene crossover sheet doors designed to minimize fiber and air transfer as people pass between areas. A minimum of two layers of polyethylene sheeting shall be required for floors, walls, and the ceiling for on- site constructed decontamination units. Polyethylene crossover sheet doors shall have at least three layers of polyethylene sheeting and be weighted so as to fall into place when people pass through the area. Decontamination chamber doors shall be of sufficient height and width to enable replacement of equipment that may fail and to safely stretcher or carry an injured worker from the site without destruction of the chamber or unnecessary risk to the integrity of the work area. Such doors must be at least four feet wide, and the distance between sets of doors must be at least four feet.
2. The decontamination unit shall consist of the following:
i. Clean room: In this room persons remove and leave all street clothes and put on clean disposable coveralls. Appropriate NIOSH approved respiratory protection equipment is also picked up in this area. No asbestos contaminated items are permitted in this room. The front entrance shall be equipped with a lockable louvered door to prevent unauthorized entry.
ii. Shower room: this is a separate room used for transit by cleanly dressed people entering the work area from the clean room and for showering by them after they have undressed in the equipment room. This is a contaminated area.
iii. Equipment room: Work equipment, footwear, and all other contaminated work clothing shall be stored here. This is also a change and transit room for people. All areas between the shower room and work area shall be considered part of the equipment room. This is a contaminated area.
iv. Each room shall be separated by individual airlock.
3. In order to prevent contamination of the environment, the contractor shall be responsible for controlling access at the work area and shall maintain a daily log of personnel entering the work area. A list of names of workers shall be posted with, their start and stop times for each day. In addition, the contractor shall ensure that all persons who enter the work area shall observe the following work area entry and exit procedures.
NYC-WTC 000104863
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
17 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
10 shared non-person entities · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112116
NYC DEP emergency notification form documenting an urgent asbestos abatement situation at 250 Vesey Place requiring immediate action.
10 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125579
Technical specifications document prepared for asbestos abatement work at the 130 Cedar Street site.
11 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135560
Application for permits regarding exterior remediation work at World Trade Center vicinity buildings.
6 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗14 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
14 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098577
Contract specifications outlining site decontamination and asbestos disposal procedures for 53 Park Place.
9 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗13 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107379
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
7 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127792
NYC DEP Asbestos Project Notification form for abatement activities at a facility in the Phase 1 Decontamination Plan binder.
7 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer
NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
Cited alongside this record in an Ask answer
NYC-WTC_000106110
Department of Environmental Protection advisory concerning air quality for building owners south of 14th Street following the WTC collapse.
Cited alongside this record in an Ask answer
NYC-WTC_000128550
Asbestos inspection report notification form submitted to NYC DEP for 102-104 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000142697
Report detailing air quality monitoring efforts and health precautions for residents regarding dust and smoke exposure.
Cited alongside this record in an Ask answer