48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗114 LIBERTY 2 OF 2
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000155647–000155711
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
December 17, 2002 114 LIBERTY STREET REMOVAL OF DUST, DEBRIS, AND CONTAMINATED MATERIALS
I. Filters: Provide cascaded filter units on drain lines from showers or any other water source carrying contaminated water from the Work Area. Provide units with disposable filter elements as indicated below. Connect so that discharged water passes primary filter and output of primary filter passes through secondary filter. Dispose of water in sanitary sewer system.
1. Primary Filter - Passes particles 20 microns and smaller.
2. Secondary Filter - Passes particles 5 microns and smaller.
J. Shower Stall: For Wash Down Station, provide leak tight shower enclosure with integrated drain pan fabricated from fiberglass or other durable waterproof material, approximately 3' x 3' square with minimum 6' high sides and back. Structurally support as necessary for stability. Equip with hose bib, as specified in this section, mounted at approamately 4' above drain pan. Connect drain to a reservoir, pump water from reservoir through filters to a drain or store and use for amended water. Mount filters inside shower stall on back wall beneath hose bib.
K. Sump Pump: Provide totally submersible waterproof sump pump with integral float switch. Provide unit sized to pump 2 time the flow capacity of all showers or hoses supplying water to the sump, through the filters specified herein when they are loaded to the extent that replacement is required. Provide unit capable of pumping debris, sand, plaster or other materials washed off during decontamination procedures without damage to mechanism of pump. Adjust float switch so that a minimum of 3" remains between the top of the liquid and the top of the sump pan.
L. Contamination Control Flooring - as manufactured by Jomac, Inc. of Warrington, PA or approved equal.
PART 3 - EXECUTION
3.01 PERSONAUWASTE DECONTAMINATION FACILITY:
A. This decontamination facility shall be constructed of airtight wood framing. Frame construction shall be via 2" x 4" wood studs at 16" centers, with 1/2" plywood on each wall and ceiling. Ceiling joist shall be minimum 2" x 4" construction and shall be capable of supporting workers and equipment above. The Contractor shall provide an adequate decontamination unit consisting of serial arrangement or rooms or spaces adjoining the wark area and as shown in details. Each space shall be clearly identified and separated from the others by plastic sheet doors, acceptable air locks, or other arrangements designed to minimize fiber or air transfer as people pass between areas. Airlocks shall be 3.0 feet in width.
B. At each end of the facility, the Contractor shall construct plywood doors on hinges. The interior of each door shall be fitted with a clasp to prevent entry while work is being performed. The exterior door of the facility shall be fitted with a padlock to prevent unauthorized access into the work area. Construction warning signs shall be hung on both doors, and doors will be fitted with louvers to facilitate airflow.
C. The location of the decontamination units shall be as per State and local regulations and, as approved by Ambient Group, Inc.
46 © AMBIENT GROUP, INC. -2002 DECONTAMINATION UNITS
NYC-WTC_000155698
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
47 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155168
Draft cleaning procedures and contract documentation for 114 Liberty with minor revisions, shared with EPA for review and comment.
8 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
14 shared non-person entities · Same agency, volume and box · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000138892
Forwarding draft cleaning procedures for 114 Liberty Street to EPA for review and comments.
8 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 114 Liberty Street · 9 pages · confidence 0.15 · verify page 1
- 114 UBERTY ST · 1 pages · confidence 0.15 · verify page 2
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Cited alongside this record in an Ask answer
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer