Fax cover sheet, JVN Restoration Inc., Sep 2002

Machine-extracted title · confidence 90%

Facsimile cover sheet from JVN Restoration Inc. dated September 25, 2002, regarding work at 124 Liberty Street.

NYC-WTC_000097267–000097269

Folder label: “124 Liberty St

Page image
Scanned page image, NYC-WTC_000097269
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM :'.JUN RESTORATION I NC FAX ND. : 7186854320 S. . 29 2002 04: 32FM F3

7. If at any tine a worker has to pass through an uncontatulnated area to access a remote decoutantinñon unit or the next work area, the shall don two suits of PPE, remove one suit while in the work area, wet wipe the inner suit, don a clean suit and proceed either to the next work area or the deconiarniasoion unit. 8. The asbestos worse area, 3ecantatnu ion unit shall be cordoned off at a distance of 25 feet and shall remain vacated except for certified workers until final clearance it met. 9. Asbestos-con sminatod tools! equipment shall be decontaminated by utilizing a waste decontamination enclosure system that complies with 56-10 or by utility a personal decontamination urt in conjunction with the applicable requirements of Subpart 56-5.1 of this code rule. 10. After the removal is complete, an authorized and qualified individual; independent of the removal contractor. (Project monitor), shall determine if the roof removal area is dry. When acceptable results are attained the area shall be encapsulated aad new roofing materials may be installed. 11. Air monitoring per this code rule 56-17 shall not be required on this project inasmuch as the roofing flashing material consists of non-friable roofn materials. We will have the air monitor run final clearance on the 3 floor and air

bag out route for the safety of others. 12. A copy of the site specifics and notifications shall be posted on decoct along with all paperwork required. 13. All other applicable provisions of industrsat Code 56-1 through 56-i? shall be complied.

NYC-WTC 000097269

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000097269Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →