ENVIROSCIENCE TEM AIR SAMPLE RESULTS
CLIENT: American Stock Exchange SAMPLE DATE: January 31, 2002
CONSULTANTS, INC.
2150 SMm-rrowN AVENUE PROJECT NAME: Papoos Resaurant RECEIVED DATE: February 1, 2002
RONKONKOMA, NEW YORK 11779
PHONE: (631) 5803191 AREA: All
FACSIMILE: (631) 580.3195 SAMPLER: L. Savarese
WWW.ENVIROHEALTH.ORG
CLIENT #: 01-10445 CUSTODY #: B-23-28
ELAP# 11681
NVLAP #200531-0
Sample # Sample Location Start End ( Run Time; Flow Rate Volume Filter Conc. Sensitivity Air Conc.
minutes Avg. Liters S/mm2 S/cc S/cc
TEM Al ': Bar/Enter 11:45 15:35 230 9 2070 0.0 0.0023 <SensitivIty
TEM A2 i Bar Access 11:50 15:38 232 9 2320 0.0 0.0021 <Sensitivity
TEM A3 Dining Window 11:55 15:42 227 9 2043 0.0 0.0024 <Sensitivity
TEM A4 Kitchen 12:00 15:46 231 9 2079 0.0 0.0023 <Sensitivity
TEM A5 i Basement 12:05 15:50 280 9 2520 0.0 0.0019 <Sensitivity
i l
I i
_____L
S=Asbestos structures,cc=cubic centimeters, mm=millimeter
Analyzed by: Date Analyzed: v " dy~ <: less than, Flow Rate in liters per minute
Samples were analyzed using Philips 400T Transmission Electron Microscope. Asbestos identification is determined by the morphology, visual Selected Area Electron
Diffraction (SAED), and Elemental Analysis using an Energy Dispersive X-ray Analyzer (EDAX).
Concentration on the filter is calculated by taking the number of asbestos structures and dividing by the area analyzed. Air concentration is calculated by multiplying
the effective filter area (EPA) by the filter concentration and then dividing by the volume of air collected in cubic centimeters (cc).
The data pertaining to these calculations can be found on the Asbestos Count Sheet.
The air filter concentration relates only to air fiber content. When samples are submitted by an outside agency for analysis, Enviroscience. can only guarantee the
accuracy of the filter concentration. This report may not be reproduced without the express permission of Enviroscience. This report can not be used to claim
endorsement of products by NVLAP or any agency of the U.S. Government.
The samples collected in the response action area demonstrated a filter concentration of asbestos less than seventy structures per square millimeter. This response
action is considered complete according to EPA 40 CFR 763.
A result of zero structures per square millimeter is only applicable to the area analyzed. Test results only reflect conditions at the time samples were taken.
NYC-WTC 000095115
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000095115Source: NYC Law Department, mirrored locally