Asbestos TEM air sample results, 86 Trinity Place, Jan 2002

Machine-extracted title · confidence 95%

Laboratory report showing transmission electron microscopy results for asbestos in air samples from January 31, 2002.

NYC-WTC_000094534

Folder label: “86 TRINITY PLACE Block: 51 Lot: 13

Page image
Scanned page image, NYC-WTC_000094534
OCR text

OCR status: ocr · source: ours

NYC-WTC 000094534 ENVIROSCIENCE CONSULTANTS, INC. 2150 SMITHTOWN AVENUE RONKONKOMA, NEW YORK 1 1779 PHONE: (631) 580-3191 FACSIMILE: (631) 580-3195 WWW.ENVIROHEALTH.ORG ELAP#11681 NVLAP #200531-0 Sample #, TEM A1 |Bar/Enter TEM A2 Bar Access TEM A3 Dining Window TEM A4 Kitchen TEM A5 | Basement Sample Location TEM AIR SAMPLE RESULTS CLENT: American Stock Exchange SAMPLE DATE: January 31, 2002 PROJECT NAME: Papoos Resaurant RECEIVED DATE: February 1, 2002 AREA: All SAMPLER: L. Savarese CLIENT#: 01-10445 CUSTODY#: B-23-28 Start! 11:45| 15:35 11:50 _15:38- 11:55 15:42 12:00 15:46 12:05 15:50 Run Time Flow Rard Volume Filter Conc. ( Sensitivity minutes AVg. Liters S/mm2 S/cc 230 2070 0.0 0.0023 232 2320 0.0 0.0021 227 2043 0.0 0.0024 231 2079 0.0 0.0023 280 2520 0.0 0.0019 Analyzed by: Ellnsot Date Analyzed: 2•5.02 S=Asbestos structures, co=cubic centimeters, mm=millimeter «= less than, Flow Rate in liters per minute Samples were analyzed using Philips 400T Transmission Electron Microscope. Asbestos identification is determined by the morphology, visual Selected Area Electron Diffraction (SAED), and Elemental Analysis using an Energy Dispersive X-ray Analyzer (EDAX). Concentration on the filter is calculated by taking the number of asbestos structures and dividing by the area analyzed. Air concentration is calculated by multiplying the effective filter area (EFA) by the filter concentration and then dividing by the volume of air collected in cubic centimeters (cc). materconcentration is calculated by mutiplying The data pertaining to these calculations can be found on the Asbestos Count Sheet. The air filter concentration relates only to air fiber content. When samples are submitted by an outside agency for analysis, Enviroscience. can only guarantee the accuracy of the filter concentration. This report may not be reproduced without the express permission of Enviroscience. This report can not be used to claim endorsement of products by NVLAP or any agency of the U.S. Goverment. The samples collected in the response action area demonstrated a filter concentration of asbestos less than seventy structures per square millimeter. This response action is considered complete according to EPA 40 CFR 763. A result of zero structures per square millimeter is only applicable to the area analyzed. Test results only reflect conditions at the time samples were taken. Air Conc. S/cc <Sensitivity <Sensitivity <Sensitivity <Sensitivity <Sensitivity NYC 9/11 Public Portal Document

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000094534Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →