CLIENT:
American Stock Exchange
PROJECT NAME: SIAC Computer Room
¡AREA:
CLIENT#:
01-10445
TEM AIR SAMPLE RESULTS
SAMPLE DATE: December 3,2001
RECEIVED DATE: December 6, 2001
Ambient
SAMPLER:
L. Savarese
CUSTODY #:
B-14-02
Sample#
TEM AI LI workshop.
TEM AZ L.2 fax/computer rack
TEM A3 |L3 desk/console
TEM A4
ILA ACI
Sample Location
Start
8:55
2:50
10:10
End
9:15
9:18
9:20
10:20
Run Time Flow Rate
| Volume
Filter Conc.
AVB.
Liters
S/mm2
1460
1436
1410
1460
2.14
3066
0.0
3.15
4451
0.0
7.35
10293
0.0
2.5
3066
0.0
Sensitivity
S/cc
0.0016
0.0011
0.0005
0.0016
Analyzedby:Ph wtaDate Analyzed: 126601
S=Asbestos structures, cc=cubic centimeters, mm-millimeter
<= less than, Flow Rate in liters per minute
Samples were analyzed using Philips 400T Transmission Electron Microscope. Asbestos identification is determined by the morphology, visual Selected Area Electron
Diffraction (SAED), and Elemental Analysis using an Energy Dispersive X-ray Analyzer (EDAX).
Concentration on the filter is calculated by taking the number of asbestos structures and dividing by the area analyzed. Air concentration is calculated by multiplying
the effective filter area (EFA) by the filter concentration and then dividing by the volume of air collected in cubic centimeters (cc).
The data pertaining to these calculations can be found on the Asbestos Count Sheet.
The air filter concentration relates only to air fiber content. When samples are submitted by an outside agency for analysis, Enviroscience. can only guarantee the
accuracy of the filter concentration. This report may not be reproduced without the express permission of Enviroscience. This report can not be used to claim
endorsement of products by NVLAP or any agency of the U.S. Government.
The samples collected in the response action area demonstrated a filter concentration of asbestos less than seventy structures per square millimeter. This response
action is considered complete according to EPA 40 CFR 763.
A result of zero structures per square millimeter is only applicable to the area analyzed. Test results only reflect conditions at the time samples were taken.
Air Conc.
S/cc
<Sensitivity
Sensitivity
«Sensitivity
<Sensitivity
OCR can misread numbers and units. Confirm readings against the page image before using them.