NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/104 TRINITY PLACE Block: 52 Lot: 15
Document / 1 page

Air sampling results memo, Trinity Place, Jan 31 2002

Machine-extracted title · confidence 95%

Memo from Enviroscience Consultants reporting ambient air sampling results conducted on January 31, 2002, at the Exchange building.

NYC-WTC_000095115

Folder label: “104 TRINITY PLACE Block: 52 Lot: 15

Page image
Scanned page image, NYC-WTC_000095115
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L

ENVIROSCIENCE TEM AIR SAMPLE RESULTS CLIENT: American Stock Exchange SAMPLE DATE: January 31, 2002 CONSULTANTS, INC. 2150 SMm-rrowN AVENUE PROJECT NAME: Papoos Resaurant RECEIVED DATE: February 1, 2002 RONKONKOMA, NEW YORK 11779 PHONE: (631) 5803191 AREA: All FACSIMILE: (631) 580.3195 SAMPLER: L. Savarese WWW.ENVIROHEALTH.ORG CLIENT #: 01-10445 CUSTODY #: B-23-28 ELAP# 11681 NVLAP #200531-0

Sample # Sample Location Start End ( Run Time; Flow Rate Volume Filter Conc. Sensitivity Air Conc. minutes Avg. Liters S/mm2 S/cc S/cc TEM Al ': Bar/Enter 11:45 15:35 230 9 2070 0.0 0.0023 <SensitivIty TEM A2 i Bar Access 11:50 15:38 232 9 2320 0.0 0.0021 <Sensitivity TEM A3 Dining Window 11:55 15:42 227 9 2043 0.0 0.0024 <Sensitivity TEM A4 Kitchen 12:00 15:46 231 9 2079 0.0 0.0023 <Sensitivity TEM A5 i Basement 12:05 15:50 280 9 2520 0.0 0.0019 <Sensitivity

i l

I i _____L S=Asbestos structures,cc=cubic centimeters, mm=millimeter Analyzed by: Date Analyzed: v " dy~ <: less than, Flow Rate in liters per minute Samples were analyzed using Philips 400T Transmission Electron Microscope. Asbestos identification is determined by the morphology, visual Selected Area Electron Diffraction (SAED), and Elemental Analysis using an Energy Dispersive X-ray Analyzer (EDAX). Concentration on the filter is calculated by taking the number of asbestos structures and dividing by the area analyzed. Air concentration is calculated by multiplying the effective filter area (EPA) by the filter concentration and then dividing by the volume of air collected in cubic centimeters (cc). The data pertaining to these calculations can be found on the Asbestos Count Sheet. The air filter concentration relates only to air fiber content. When samples are submitted by an outside agency for analysis, Enviroscience. can only guarantee the accuracy of the filter concentration. This report may not be reproduced without the express permission of Enviroscience. This report can not be used to claim endorsement of products by NVLAP or any agency of the U.S. Government. The samples collected in the response action area demonstrated a filter concentration of asbestos less than seventy structures per square millimeter. This response action is considered complete according to EPA 40 CFR 763. A result of zero structures per square millimeter is only applicable to the area analyzed. Test results only reflect conditions at the time samples were taken.

NYC-WTC 000095115

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095115Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →