NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\MSDCHEM\l\DATA\050202\10187 .D Vial: 23
Acq On 2 May 2002 7:46 pm Operator: Bohlk / Inst 213
Sample SAMPLE 10187 4/30/02 Inst : Instrumen
Mise Multiplr: 1.00
MS Integration Params: rteint.p
Quant Time: May 06 15:02:31 2002 Quant Results File: 050102.RES
Quant Method : C:\MSDCHEM\l\5973N\050102.M (RTE Integrator)
Title : Quantitation For Method 525.2
Last Update : Mon May 06 12:42:26 2002
Response via : Initial Calibration
DataAcq Meth : 050102
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) Acenaphthene-dlO 17.59 164 2887198 5.00 ug/L 0.00
9) Phenanthrene d-lO 21.89 188 4561612 5.00 ug/L 0.00
19) Chrysene d-12 29.62 240 3035920 5.00 ug/L 0.00
25) p-Terphenyl d-14 26.77 244 3516352m 5.00 ug/L 0.00
System Monitoring Compounds
2) 1,3-Dimethyl-2-nitrobenzen 12.55 134 770338 5.84 ug/L 0.00
Spiked Amount 5.000 Recovery = 116.80%
20) Triphenyl Phosphate 2 8.94 326 842496 6.23 ug/L 0.00
21) Perylene D-12 33.60 264 355754 0.84 ug/L 0.00
Spiked Amount 5.000 Recovery = 16.80%
26) Acenaphthene d-10 (surr) 17.59 164 2887198 3.30 ug/L 0.00
Spiked Amount 5.000 Recovery = 66.00%
27) Phenanthrene d-10 (surr) 21.89 188 4561612 3.82 ug/L 0.00
Spiked Amount 5.000 Recovery = 76.40%
28) Chrysene d-12. (surr) 29.62 240 3035920 3.83 ug/L 0.00
Spiked Amount 5.000 Recovery = 76.60%
Target Compounds Qvalue
3) Hexachlorocyclopentadiene 0.00 237 0 N.D.
4) Hexachlorobenzene 0.00 284 0 N.D.
5) EPTC 0.00 128 0 N.D. .
6) 2,6-Dinitrotoluene 0.00 165 0 N.D. d
7) 2,4-Dinitotoluene 0.00 165 0 N.D. d
8) Molinate 0.00 126 0 N.D.
10) Simazine 0.00 201 0 N.D.
11) Atrazine 0.00 200 0 N.D.
12) Alachlor 0.00 160 0 N.D.
13) Terbacil 0.00 117 0 N.D.
14) Acetochlor 0.00 146 0 N.D.
15) Metribuzin 0.00 198 0 N.D.
16) Metolachlor 0.00 162 0 N.D.
17) Butachlor 0.00 160 0 N.D. d
18) 4,4’-DDE 0.00 246 0 N.D. d
22) Bis (2-Ethylhexyl) adipate 0.00 129 0 N.D. d
23) Bis (2-Ethylhexyl) phthala 30.31 149 195093 1.54 ug/L 89
24) Benzo (a) pyrene 33.47 252 22029m 0.80 ug/L
(#) = qualifier out of range (m) = manual integration
10187.D 050102.M Mon May 06 17:53:17 2002 Page 1
NYC-WTC_000082585
OCR can misread numbers and units. Confirm readings against the page image before using them.