NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 60/GCMS Scan X 10/10/01 An 11/1/01
Document / 11 pages

GCMS calibration table for TCLP analysis, Nov 2 2001

Machine-extracted title · confidence 100%

Calibration data table for GCMS TCLP analysis listing surrogate compounds and response factors from November 2, 2001.

NYC-WTC_000067979–000067989

Folder label: “GCMS Scan X 10/10/01 An 11/1/01

Page image
Scanned page image, NYC-WTC_000067981
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed) Data File s C:\HPC3IEM\1\DATA\OCT3101\LB.D Vial: 2 Acq On : 31 Oct 2001 5:05 pm Operator: 209 GALOS Sample : 10/10 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Nov 2 16:42 2001 Quant Results File: NP103001.RES Quant Method : C:\HPCHEM\1\METHODS\NP103001.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri Nov 02 16:41:16 2001 Response via : Initial Calibration DataAcq Meth : NP101901

Con^jound R.T. Qlon Response Cone Unit Qvalue 71) Benzo(k)fluoranthene 0.00 252 0 N.D. 72) Benzo(a)pyrene 37.16 252 3667 N.D. 73) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 74) Dibenz(a,h)anthracene 0.00 278 0 N.D. 75) Benzo (g,h, Dperylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration LB.D NP103001.M Fri Nov 02 16:46;,44 2001 Page 3

NYC-WTC_000067981

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000067981Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

GCMS sample extraction log table, Nov 2001 · Box DEP Box 60

NYC-WTC_000068400

Multi-page laboratory log table recording sample extraction details including volumes and drip rates for GCMS analysis in November 2001.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →