NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 60/GCMS Scan X 10/22/01 An 11/8/01
Document / 9 pages

GC/MS calibration report, Nov 6 2001

Machine-extracted title · confidence 95%

Calibration data for GC/MS analysis including naphthalene and phenanthrene standards dated November 6, 2001.

NYC-WTC_000069271–000069279

Folder label: “GCMS Scan X 10/22/01 An 11/8/01”

Page image
Scanned page image, NYC-WTC_000069273
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed) Data File : C;\HPCHEM\l\DATA\N0V2601\LB.D Vial: 8 Acq On : 26 Nov 2001 5:32 pm Operator: 209 GALOS Sample : 10/22 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Nov 26 18:20 2001 Quant Results File: NP103001.RES Quant Method : C:\HPCHEM\1\METHODS\NP103001.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri Nov 02 16:41:16 2001 Response via : Initial Calibration DataAcq Meth : NP103001

Compound R.T. Qlon Response Cone Unit Qvalue 71) Benzo(k)fluoranthene 36.12 252 16296 N.D. 72) Benzo(a)pyrene 36.95 252 8366 N.D. 73) Indeno(1,2,3-cd)pyrene 40.83 276 4307 N.D. 74) Dibenz(a,h)anthracene 40.89 278 2997 N.D. 75) Benzo (g,h, Dperylene 41.90 276 5706 N.D.

(#) = qualifier out of range (m) = manual integration LB.D NP112601.M Tue Nov 27 09:24:59 2001 Page 3

NYC-WTC_000069273

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000069273Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

GCMS sample extraction log table, Nov 2001 · Box DEP Box 60

NYC-WTC_000068400

Multi-page laboratory log table recording sample extraction details including volumes and drip rates for GCMS analysis in November 2001.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.994

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →