NYC-WTC_000044723
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Calibration data for GC/MS analysis of surrogate compounds including dichlorobenzenes and naphthalene from April 2002.
NYC-WTC_000043726–000043734Folder label: “GCMS X 4/24/02 A 5/3/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Data File : C:\HPCHEM\l\DATA\APR2302\8934.D Vial: 14 ' Acq On : 24 Apr 2002 3:05 am Operator: Sample : gc/ms scan 4/15 Inst : 209 Mise : Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS0412.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC
peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 8.188 338 342 347 rBV 317666 656169 15.13% 3.014% 2 12.209 775 780 794 rVB 1254123 2933154 67.63% 13.472% 3 14.807 1058 1063 1068 rBV 31434 59615 1.37% 0.274% 4 15.844 1170 1176 1193 rBV 1870670 3810218 87.85% 17.501% 5 21.150 1747 1754 1767 rBV 2065924 4337066 100.00% 19.921%
6 23.280 1980 1986 1992 rBV 156054 306954 7.08% 1.410% 7 25.585 2230 2237 2248 rBV2 1913322 4164793 96.03% 19.130% 8 25.722 2248 2252 2262 rVB 16059 45808 1.06% 0.210% 9 33.645 3107 3115 3132 rBV2 1364784 3128697 72.14% 14.371% 10 37.877 3567 3576 3598 rBV2 748099 2328973 53.70% 10.697%
Sum of corrected areas: 21771447
8934.D GCMS0412.M Wed Apr 24 08:38:50 2002
NYC-WTC_000043729
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000044723
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043678
Calibration table for GC/MS analysis listing deuterated standards and their response values from April 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044621
Calibration scan report for EPA Method 625 showing retention times and deviations for deuterated standards on April 25 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044700
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044748
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044650
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023345
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09518 analyzed in May 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023363
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09520 analyzed in May 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000044584
Reference analysis report for GCMS testing of volatile organic compounds with quantified concentrations recorded on May 8 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044723
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044621
Calibration scan report for EPA Method 625 showing retention times and deviations for deuterated standards on April 25 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044650
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044748
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023372
Laboratory report showing GC/MS analysis results for sample AE09446 including surrogate recovery data on May 16, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000043641
Single-page administrative log from DEP Box 25 covering GCMS X analyses dated between April 24 and May 3, 2002.
Filed in the same folder
NYC-WTC_000043642
Technical record of GC/MS analytical parameters and sample processing details for the batch dated May 2002.
Filed in the same folder
NYC-WTC_000043646
Laboratory report documenting a GC/MS blank run to check for contamination in the analytical system on May 6, 2002.
Filed in the same folder
NYC-WTC_000043655
Calibration report listing target compounds and their concentrations for the GC/MS analysis performed on May 6, 2002.
Filed in the same folder
NYC-WTC_000043659
Report detailing the response values for GC/MS reference standards used to verify instrument performance on May 6, 2002.
Filed in the same folder