NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\JAN0 302\29520.D Vial: 16
Acq On 4 Jan 2002 1:12 am Operator: 209 GALOS
Sample gems scan Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Jan 4 2:00 2002 Quant Results File: GCMS1126.RES
Quant Method C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title 209 625/TCLP calibration table
Last Update Fri Dec 28 15:11:00 2001
Response via Initial Calibration
DataAcq Meth GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.53 152 1410988 20.00 ug/1 -0.17
10) Naphthalene-d8 15.13 136 5432851 20.00 ug/1 -0.18
17) Acenaphthene-diO 20.40 164 2653891 20.00 ug/1 -0.18
29) Phenanthrene-diO 24.81 188 3977031 20.00 ug/1 -0.18
38) Chrysene-dl2 32.84 240 2350349 20.00 ug/1 -0.19
44) Perylene-dl2 36.91 264 1422203 20.00 ug/1 -0.21
System Monitoring Compounds
37) 2,4-DDD 29.89 235 169303 3.87 ug/mL -0.18
Spiked Amount 5.000 Recovery = 77.40%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.13 74 212 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 12.82 117 179 N.D.
11) Nitrobenzene 13.15 77 183 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.18 128 4604 N.D. ■
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 19.96 165 185 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 20.41 153 138 N.D.
24) 2,4-Dinitrotoluene 21.15 165 367 N.D.
25) Diethylphthalate 21.91 149 1220 N.D.
26) 4-Chlorophenyl-phenylether 0.00 2 04 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
29520.D GCMS1126.M Tue Jan 08 10:22:39 2002 Page 1
NYC-WTC_000036544