NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\l\DATA\DEC1401\29781.D Vial 48
Acq On 16 Dec 2001 12:35 pm Operator 209 GALOS
Sample gems scan 12/11 Inst GC/MS 209
Mise Multiplr 1.00
MS Integration Params: GOOFY.P
Quant Time: Dec 28 14:50 2001 Quant Results File: GCMS1126.RES
Quant Method C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title 209 625/TCLP calibration table
Last Update Fri Dec 14 12:19:30 2001
Response via Initial Calibration
DataAcq Meth GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.68 152 860066 20.00 ug/1 -0.02
10) Naphthalene-d8 15.27 136 3290710 20.00 ug/1 -0.03
17) Acenaphthene-diO 20.55 164 1644834 20.00 ug/1 -0.02
29) Phenanthrene-dl .24.97 188 2380262m 20.00 ug/1 -0.02
38) Chrysene-dl2 33.01 240 1474807 20.00 ug/1 -0.02
44) Perylene-dl2 37.10 264 928955 20.00 ug/1 -0.02
System Monitoring Compounds
37) 2,4-DDD 30.05 235 131835 3.83 ug/mL -0.02
Spiked Amount 5.000 Recovery = 76.60%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.19 74 818 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2‘-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.33 128 1598 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.09 165 316 N.D.
25) Diethylphthalate 22.10 149 798 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
29781.D GCMS1126.M Fri Dec 28 14:51:01 2001 Page 1
NYC-WTC_000037199
OCR can misread numbers and units. Confirm readings against the page image before using them.