Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\l\DATA\DEC3101\29666.D Vial: 64
Acq On 3 Jan 2002 3:59 am Operator: 20 9 GALOS
Sample gems scan Y2.I7 Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Jan 16 9:06 2002 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Fri Dec 28 15:11:00 2001
Response via : Initial Calibration
DataAcq Meth : GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.68 152 1088063 20.00 ug/1 -0.02
10) Naphthalene-d8 15.28 136 4185801 20.00 ug/1 -0.02
17) Acenaphthene-diO 20.56 164 2024455 20.00 ug/1 -0.01
29) Phenanthrene-dlO 24.99 188 2934081m 20.00 ug/1 0.00
38) Chrysene-dl2 33.02 240 1858490 20.00 ug/1 -0.01
44) Perylene-dl2 37.11 264 1137169 20.00 ug/1 0.00
System Monitoring Compounds
37) 2,4-DDD 30.06 235 115828 3.59 ug/mL 0.00
Spiked Amount 5.000 Recovery = 71.80%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.15 74 2786 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybis(1-Chloropropan 0.00 45 0 ■ N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 13.19 77 543 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzehe 0.00 180 0 N.D.
15) Naphthalene 15.33 128 1342 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.21 165 420 N.D.
25) Diethylphthalate 22.17 149 655 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
29666.D GCMS1126.M Wed Jan 16 09:07:27 2002 Page 1