NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
NYC-WTC_000035135–000035152Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File : C:\HPCHEM\l\DATA\DEC0401\28694.D Vial: 5 Acq On 4 Dec 2001 4:16 pm Operator: 209 GALOS Sample : gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 2 Tetracosane Concentration Rank 9 R.T. EstConc Area Relative to ISTD R.T. 29.55 0.51 ug/1 124756 Chrysene-dl2 33.04 Hit# of 5 Tentative ID MW MolForm CAS# Qi
1 Tetracosane 338 C24H50 000646-31-1/91 2 Eicosane 282 C20H42 000112-95-8 91 3 Heptadecane 240 C17H36 000629-78-7 91 4 Hexadecane ____________ 226 C16H34 000544-76-3 9 Abundance Scan 2670 (29.553 min): 28694.D (-) m/z 56.95 100.00% 57 43 71
5000 85 . — . A....... 29.20 29.40 29.60 29.80 ...................................................................................................... m/z71.00 74.28% TIT THr mfe-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance #73543: Tetracosane 43 5 7 71
5000 85 1 Dr 1 , 4W 29.20 29.40 29.60 29.80 99 m/z43.05 72.52% । (| 113127 155169183197 294 338 11P'1111 rT‘I—UImuuuuuutuut"‘uu"———u0"EI0OWITTTTT.. .. n/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance 43 57 71 #72326: Eicosane
A 29.20 29.40 29.60 29.80 m/z 85.00 48.02% 5000 85
। 99. L L . .................... ......... . ............ m/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance #71193: Heptadecane . 4 iii 0004 57 29.20 29.40 29.60 29.80 m/z 41.05 33.14% 71 5000 85 .... ............. ............................... 99 J 113127141155169 210 240 n I ■1 I’’ TI——mu—g—u0umuamgugunp"nnuumgr m/z—> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 29.20 29.40 29.60 29.80
28694.D GCMS1126.M Thu Dec 06 15:34:00 2001 Page 2
NYC-WTC_000035142
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088853
Laboratory report documenting GC/MS analysis of sample AD23501 conducted on October 19, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087274
Laboratory report documenting GC/MS analysis of sample AD22652 conducted on October 11, 2001, identifying unknown compounds.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder