NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
NYC-WTC_000035026–000035043Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Library Search Compound Report
Data File : C:\HPCHEM\1\DATA\DECO401\28688.D Vial: 6 Acq On 4 Dec 2001 5:15 pm Operator: 209 GALOS Sample : gc/ms 11/24 Inst : GC/MS 209 Misc Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 1 Silane, tetramethyl- Concentration Rank 3 R.T. EstConc Area Relative to ISTD R.T. --------------------------------------------------------------------- 7.66 1.10 ug/1 233949 1,4-Dichlorobenzene-d4 11.71
Hit# of 5 five ID MW MolForm CAS# Qual -------------- ------------------------------------------------- 1 Silane, tet yl- 88 C4H12Si 000075-76-3 43 2 N-Ethylform/ide 73 C3H7NO 000627-45-2 9 3 1,3-Dioxola (3-bromo-5,5,5-tri 352 C10H16BrC13O2 000000-00-0 9 4 2-Butanone, 3-methoxy-3-methyl- 116 C6H1202 036687-98-6 9 undance Scan 284 (7.655 min): 28688.D (-) m/z 73.00 100.00%
5000 43 7.40 7.60 7.80 8.00 36 49 55 67 87 103 m z 43.05 26.42% rfz-> 10 20 30 40 50 60 70 80 90 100 110 120 Abundance #845: Silane, tetramethyl- 73
5000 7.40 7.60 7.80 8.00 m/z 41.05 11.15% 15 31 55 g8 -> 10 20 30 40 50 60 70 80 90 100 110 120 undance #292: N-Ethyfformamide
73 7.40 7.60 7.80 8.00 5000 m/z 44.95 9.73% 44 58
15
-> .10 20 30 40 50 60 70 80 90 100 110 120 bundance #49423: 1,3-Dioxolane, 2-(3-bromo-5,5,5-trichloro-2,2-dimet • 7 7.40 7.60 7.80 8.00 m/z 71.00 5.64% 5000
45 36 II 55 67 109115 iJz-> 10 20 30 40 50 60 70 80 .90 100 110 120 7.40 7.60 7.80 8.00
28688.D GCMS1126.M Thu Dec 06 13:23:06 2001 Page 1
NYC-WTC 000035032
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder