NYC-WTC_000036341
Calibration log for GCMS analysis of sample AD29289 listing target analytes and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
NYC-WTC_000034954–000034957Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Jser: Galos, Marie Vestchester Dept. of Labs & Research late: 12/07/2001 Time: 16:04:49
Sample: AD28662 inalysis: $C1GCMS ।CALI GCMS Jnits: ug Started: 12/4/20 00:09 Ended: 12/4/20 00:09 Analyst: MG Result source: m:\instruments\209\data\dec0401\cal80.d\cal8O.rr ’age: 1
— Component Name 0 Viol Result s MDLWEE _1 ; n-Nitrosodimethylamine 92 2.0 2 bis(2-Chloroethyl )ether 75 2.0 13 1,3-Dichlorobenzene 76 2.0 14 7 1,2-Dichlorobenzene 1,4-Dichlorobenzene 74 2.0 5. 2,2'-oxybis( 1 -Chloropropane) 72 . 78 2.0 16 2.0 7 ' n-Nitrosodi-n-propylamine 82 ”2.0
8 Hexachloroethane 2.0 9 Nitrobenzene 79 2.0 10 Isophorone 80 2.0 11 ’ bis(2-Chioroethoxy)methane 74 2.0 12/ 1,2,4-Trichlorobenzene 70 2.0 13 Naphthalene 69 2.0 14 Hexa chlorobutadiene 73 2.0 15 16 Hexachlorocyclopentadiene 2-Chloronaphthalene 100 76 2.0 2.0 17 Dimethylphthalate 80 ...... 2.0 18 2,6-Dinitrotoluene 84 _______ 2.0_____ 19 •' Acenaphthylene 77 2.0 20 . Acenaphthene 73 2.0 21 2,4-Dinitrotoluene 84 2.0 22 Diethylphthalate 77 67 2.0 23 4-Chlorophenylphenylether 2.0 24 ' Fluorene 67 2.0 25. Azobenzene/1,2-Diphenylhydraz 80 2.0 26 n-Nitrosodiphenylamine 76 2.0 27 4-Bromophenylphenylether 75 2.0 28 “ Hexachlorobenzene 72 2.0 29 Phenanthrene 69 2.0 30 Anthracene 70 2.0 31 Di-n-butylphthalate 70 2.0 32 Fluoranthene 73 2.0 33 1 Pyrene 70 2.0 34 Butyl benzylphthalate 69 2.0 35 Benzo(a)anthracene 75 2.0 36 bis(2-Ethylhexyl)phthalate 62 2.0 37 Chrysene 73 66 2.0 2.0 38 Di-n-octylphthalate 39 Benzo(b)fluoranthene 77 2.0 40 Benzo(a)pyrene Benzo(k)fluoranthene 71 2.0 2.0 41 Indeno(1,2,3-cd)pyrene 78 42 84 84 2.0 43 Dibenz(a,h)anthracene 2.0 44 Benzo(g,h,i)perylene 84 2.0
NYC-WTC_000034954
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000036341
Calibration log for GCMS analysis of sample AD29289 listing target analytes and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035571
GCMS method blank analysis for sample AD28903 dated December 7, 2001, showing non-detect levels.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035435
Laboratory report of a method blank analyzed on December 16, 2001, showing non-detect results for target compounds.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036055
Laboratory report listing detection limits for various organic compounds in a GCMS blank sample run on December 18.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036201
Laboratory record documenting the extraction method parameters for sample AD29229 analyzed in December 2001.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035900
Calibration data sheet verifying instrument response for nitrosamines and benzene derivatives.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036494
Laboratory calibration data sheet for GCMS analysis of organic compounds including nitrosamines and chlorobenzenes dated December 13, 2001.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034727
Calibration results for gas chromatography-mass spectrometry analysis showing detector responses for standard compounds.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035240
Calibration record verifying instrument response factors for specific chemical compounds prior to analysis.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035674
Calibration data sheet verifying instrument response for nitrosamines and benzene derivatives.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000017894
Laboratory report documenting gas chromatography-mass spectrometry reference material analysis conducted on December 31, 2001.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000034727
Calibration results for gas chromatography-mass spectrometry analysis showing detector responses for standard compounds.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034759
Laboratory analyst notes on GCMS scan results and recovery rates for sample AD28595 analyzed in early December 2001.
Similarity score 0.939 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035274
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
Similarity score 0.939 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Similarity score 0.939 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035505
Gas chromatography-mass spectrometry analysis results for sample AD28859 showing bis(2-Ethylhexyl)phthalate presence at 0.81 ug/L with quality control notes on LCS standard recover
Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035298
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
Filed in the same folder