NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09578 analyzed in May 2002.
NYC-WTC_000023327–000023334Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Data File C:\HPCHEM\1\DATA\MAY0302\9578 .D Vial: 51 . Acq On 5 May 2002 5:01 pm Operator: Sample GC/MS SCAN 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5 Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total 1 8.160 336 340 346 rBV 807694 1568607 40.89% 7.693% 2 12.192 771 780 795 rBV 1235491 2762290 72.00% 13.547% 3 14.794 1058 1064 1070 rVB 190106 367038 9.57% 1.800% 4 15.830 1171 1177 1193 rVB 1643130 3478783 90.67% 17.061% 5 21.135 1749 1756 1772 rBV 1833866 3836567 100.00% 18.815% 6 23.270 1983 1989 1995 rVB 87170 175853 4.58% 0.862% 7 25.580 2234 2241 2252 rBV2 1634768 3553879 92.63% 17.429% 8 33.634 3112 3120 3139 rBV2 1196364 2615432 68.17% 12.827% 9 37.868 3573 3582 3599 rBV2 681491 2032146 52.97% 9.966%
Sum of corrected areas: 20390595 9578.D GCMS0501.M Tue May 07 15:01:58 2002
NYC-WTC_000023330
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023345
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09518 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023363
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09520 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043678
Calibration table for GC/MS analysis listing deuterated standards and their response values from April 24, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044621
Calibration scan report for EPA Method 625 showing retention times and deviations for deuterated standards on April 25 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043726
Calibration data for GC/MS analysis of surrogate compounds including dichlorobenzenes and naphthalene from April 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043124
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09396 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043112
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09395 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044650
Calibration data file listing standard compounds and response factors for TCLP testing from late April 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043124
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09396 with unknown compounds and surrogate data from May 9, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043853
Laboratory report for sample AE08016 showing unknown compounds and surrogate data from May 17, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder