NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
NYC-WTC_000023195–000023202Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
* Library Search Compound Report
Data File C : \HPCHEM\ 1 \DATA\MAYO 3 02\9577.D Vial: 50 Acq On 5 May 2002 4:02 pm Operator: Sample GC/MS SCAN 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 1 2-Pentanone, 4-hydroxy-4-methy Concentration Rank 1
R.T. EstConc Area Relative to ISTD R.T.
8.16 25.57 ug/1 1664360 1,4-Dichlorobenzene-d4 12.20
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 2-Pentanone, 4-hydroxy-4-methyl- 116 C6H1202 000123-42-2 64 2 Acetic acid, 1,1-dimethylethyl este 116 C6H1202 000540-88-5 9 3 CH2=CHCH2C (0) OCH3 100 C5H802 003724-55-8 9 4 Acetone 58 C3H60 000067-64-1 7 Abundance Scan 341 (8.163 min): 9577.D (-) m/z 43.05 100.00% 43
5000 59
1 1 i ■ ■ ■ ' i ' ■ 101 7.80 8.00 8.20 8.40 8.60 ................................... 38 I ,,^53, 69 77 83 , | ' ' i ' ■ ' ' i ' 1 ' ' i 1 ' 1 1 i ' m/z 59.10 42.48% mlz-> 10 20 30 40 50 60 70 80 90 100 110 Abundance #64274:2-Pentanone, 4-hydroxy-4-methyl- 43
5000 59 780 8.00 8.20 8.40 8.60 m/z .58.10 17.00% 27 101
niz-> 10 20 I I 30 — 40 +9+ 50 II—m—m 60 70 80 83 90 H 100 110 Abundance #3292: Acetic acid, 1,1-dimethylethyl ester 43 7 80 8.00 8.20 8.40 8.60 5000 57 m/z 101.15 13.77% 101 15 27 I t TTH 1 1 1 I ' ' 'i' । ' 1 i " " I " 1 ' i " " i ' miz—> 10 20 30 40 50 60 70 80 90 100 110 Abundance #1448: CH2=CHCH2C(O)OCH3 43 7 80 8.00 8.20 8.40 8.60 m/z 41.05 6.80%
5000
................................. i 1 ' ■ ■ i ' ■ ■ ■ i ■ ■ ■ 1 r' 58 72 ------ ' I ' 1 ' ' 1 1 100 m/z-> 10 20 30 40 50 60 70 80 90 100 110 7.80 8.00 8.20 8.40 8.60
9577.D GCMS0501.M Tue May 07 15:01:46 2002 Page 1
NYC-WTC_000023200
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023055
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022930
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023754
Laboratory report of GCMS analysis for sample AE09654 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046276
Laboratory report showing GCMS calibration data for sample AE09580 generated on May 3-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046313
Laboratory report showing GCMS calibration data for sample AE09586 generated on May 4-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046332
Laboratory report showing GCMS calibration data for sample AE09587 generated on May 4-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045490
Technical document displaying GCMS calibration data and compound retention times for sample AE09448 processed in early May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013117
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045472
Technical document displaying GCMS calibration data and compound retention times for sample AE09447 processed in early May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013277
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000045322
GCMS analytical report for sample AE10516 showing unknown compounds and surrogate recovery data from May 21, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000049167
Laboratory report documenting GCMS analysis of sample AE08836 conducted on April 25, 2002, showing detection of unknown compounds.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013251
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023055
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045423
GCMS analytical report for sample AE10607 showing unknown compounds and surrogate recovery data from May 15, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046238
Laboratory report listing GCMS results for unknown compounds and surrogates from sample AE09579 on May 17, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.