NYC-WTC_000023195
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
NYC-WTC_000023099–000023106Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document LSC Area Percent Keporc Data File C:\HPCHEM\l\DATA\MAY0302\9572 .D Vial: 46 Acq On 5 May 2002 12:06 pm Operator: Sample GC/MS SCAN 4/23 FB Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total 1 8.162 337 341 370 fVB 405280 937276 23.55% 4.595% 2 12.194 775 781 795 rBV 1288475 2869725 72.11% 14.068% 3 14.796 1059 1065 1071 rBV 199256 384432 9.66% 1.885% 4 15.822 1171 1177 1195 rBV 1714516 3637017 91.39% 17.830% 5 21.137 1750 1757 1766 rBV 1910306 3979751 100.00% 19.510% 6 23.272 1983 1990 1996 rBV 83308 162932 4.09% 0.799% 7 25.582 2235 2242 2252 rBV2 1661257 3681023 92.49% 18.045% 8 33.636 3114 3121 3139 rBV2 1178117 2669610 67.08% 13.087% 9 37.870 3574 3583 3603 rBV2 703827 2076984 52.19% 10.182%
Sum of corrected- areas: 20398750 9572.D GCMS0501.M Tue May 07 15:00:51 2002
NYC-WTC_000023102
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000023195
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023055
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022930
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023363
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09520 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023345
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09518 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023828
Laboratory report of GCMS analysis for sample AE09680 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023738
Laboratory report of GCMS analysis for sample AE10065 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046276
Laboratory report showing GCMS calibration data for sample AE09580 generated on May 3-6, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046313
Laboratory report showing GCMS calibration data for sample AE09586 generated on May 4-6, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046332
Laboratory report showing GCMS calibration data for sample AE09587 generated on May 4-6, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder