Document / 8 pages

GCMS calibration data for TCLP method, May 2002

Machine-extracted title · confidence 100%

GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.

NYC-WTC_000023055–000023062

Folder label: “GCMS X 5/8/02 A 5/9/02

Page image
Scanned page image, NYC-WTC_000023056
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (QT Reviewed) Data File C:\HPCHEM\l\DATA\MAY0302\9570.D Vial: 44 Acq On 5 May 2002 10:09 am Operator: Sample GC/MS SCAN 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 7 14:49 2002 Quant Results File: GCMS0501.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed May 01 10:40:31 2002 Response via : Initial Calibration DataAcq Meth : GCMS0501

Compound R.T. Qlon Response Cone Unit Qvalue 35) Anthracene 25.64 178 2336 N.D. 36) Di-n-butylphthalate 27.55 149 3192 N.D. 37) Fluoranthene 29.26 202 1770 N.D. 3 9) Pyrene 29.94 202 1465 N.D. 40) Butylbenzylphthalate 0.00 149 0 N.D. 41) Benzo(a)anthracene 33.63 228 4212 N.D. 42) Bis(2-ethylhexyl)phthalate 33.85 149 2662 N.D. 43) Chrysene 0.00 228 0 N.D. d 45) Di-n-Octylphthalate 35.59 149 1304 N.D. 46) Benzo(b)fluoranthene 0.00 252 0 N.D. d 47) Benzo(k)fluoranthene 0.00 252 0 N.D. d 48) Benzo(a)pyrene 37.68 252 775 N.D. 49) Indeno(1,2,3-cd)pyrene 41.95 276 714 N.D. 5 0) Dibenz(a,h)anthracene 42.00 278 266 N.D. 51) Benzo(g,h,i)perylene 43.19 276 713 N.D.

(#) = qualifier out of range (m) = manual integration 9570.D GCMS0501.M Tue May 07 14:50:31 2002 Page 2

NYC-WTC_000023056

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000023056Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →