2003 E-Mails Sent M Gilsenan — page 3
A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project
Email alerts are not offered yet — copy this link to check back after a new release.
Searching the mirrored records for “asbestos”.
A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the functions of both Monitor and Technician during this project
Summary Resident request for DEP to perform cleaning and monitoring work at an apartment in Manhattan.
Air Sau►ple Collection and Analysis L All asbestos air samples collected during clean-up activities shall be analyzed via TEM.
Summary Cover page for a Preliminary Environmental Assessment report dated January 10, 2006 for 30 West Street.
Daily sampling for asbestos has been conducted, samples have been analyzed by TEM (AHERA), and all sample results are within acceptable limits (70s/mm2).
Summary US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Clearance Criteria: Clearance testing for asbestos will be acceptable when all samples for a given work area meet the 70 structures per square millimeter TEM standard, '
Summary Report cover for a preliminary environmental assessment regarding remediation at 30 Warren Street in January 2006.
Daily sampling for asbestos has been conducted, samples have been analyzed by TEM (AHERA), and all sample
Summary A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.
84hrs/week for 72 weeks @ $40/hr = $ 2.419,200 Per diem & Lodging 10 people @ 254/day for 72 weeks = $ 1,280,160 Laboratory Contracts Asbestos
Summary Page displaying a document identification number and reference code for records associated with 200 Liberty Street.
Lead Load mg/kgappm NYC 9/11 Public Portal Document 25,680 <535 <535 1,070 10,165 <535 <535 2,140 2,140 720 0.1872 000 000 CA = Chrysotile Asbestos NVA = No Visible Asbestos VAD/NA = No Asbestos Detected FAT = Final Air Test
Summary EPA transmission of fact sheets for World Trade Center cleanup program addressing cleaning, HVAC, and other remediation topics.
Finally, your residence will be recleaned and retested if the post-cleanup testing finds levels of asbestos in excess of EPA’s cleanup goal.
Summary Distribution of World Trade Center cleanup program fact sheets addressing cleaning, HVAC, and remediation procedures.
Finally, your residence will be recleaned and retested if the post-cleanup testing finds levels of asbestos in excess of EPA’s cleanup goal.
Summary Distribution of World Trade Center cleanup program fact sheets addressing cleaning responsibilities, HVAC, and related remediation topics.
Finally, your residence will be recleaned and retested if the post-cleanup testing finds levels of asbestos in excess of EPA’s cleanup goal.
Summary Circulation of EPA fact sheets for WTC cleanup programs covering HVAC systems, contamination, and treatment procedures.
Finally, your residence will be recleaned and retested if the post-cleanup testing finds levels of asbestos in excess of EPA’s cleanup goal. NYC-WTC_000139098
Summary Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
Asbestos in indoor dust samples was similarly very high.
Summary Memo summarizing daily activities including hot sidewalk conditions and a FEMA meeting request on October 17, 2001.
; A total of 478 air aomtoriag samples for asbestos have been taken.
Summary Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
: A total of478 ah monitoriag samples for asbestos have been taken.
Summary Senator correspondence to EPA Administrator expressing concerns about environmental protection and public health following September 11 attack on World Trade Center.
Is this the case and if so, why is there co pre-e’eaning air sampling for asbestos or pre- anti post-cleaning wips sampling for other contaminants?
Summary Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Analysis of these samples included lead, MMVF, alpha-quartz and asbestos.
Asbestos and glass Although some asbestos was used in the buildings for fireproofing and in floor tiles, and the DELTA group checked for it carefully using the electron microscope, they found very few asbestos fibers
Summary A newspaper article announcing that the city will seek bids for cleaning contaminated apartments around Ground Zero at an estimated cost of $3,000 to $8,000 per unit.
The agency said the testing, along The E.PJL’s May announcement with the asbestos cleanup and testing of an asbestos cleanup program was
Summary Memo regarding EPA's expanded plan to clean and test Lower Manhattan apartments for asbestos, dioxins, and toxic metals following the World Trade Center disaster.
The E.P.A. bowed to pressure from infuriated tenants around ground zero in May, promising to clean and test apartments for asbestos.
Summary Newspaper report detailing the EPA's decision to test and clean apartments for asbestos contamination near Ground Zero.
But the program will test only for asbestos. Nadler argued that the clean- ing should be done building by building — not unit by unit — to avo: “a threat of recontamina- tion.”