Memorandum on asbestos wipe sampling and cancer risk estimation, December — page 10

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151644Machine-extracted title
Lab report

Summary EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.

Thus, the studies of humans using PCM measurements may actually have overestimated true asbestos exposures because they included non-asbestos fibers.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

DEP public affairs fax cover sheet with inquiry questions, Feb — page 2

DEP Hard Copies (68 Boxes) / DEP Box 11
NYC-WTC_000151995Machine-extracted title
Memo or letter

Summary Fax cover sheet from DEP Public Affairs dated February 1, 2002, containing questions about indoor air and dust asbestos testing.

Indoor air quality has no standards, only guidelines as published by the USEPA. 6) No, we never said not to involve EPA with asbestos, however, DEP took the lead in all asbestos-related

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, lead, particulate, pcbs, vocs

EPA letter on residential dust cleaning results, Jan 2003 — page 2

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150146Machine-extracted title
Lab report

Summary Notification from the EPA confirming that air samples taken at a residence south of Canal Street did not exceed asbestos clearance levels.

Asbestos Fibers > 5 urn Number of asbestos fibers detected greater than (>) 5 microns in length.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: actinolite, amosite, asbestos, particulate, tremolite

Environmental Monitoring Report for Battery Park City, October 2001 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150071Machine-extracted title
Lab report

Summary Summary of environmental sampling and benchmark standards used by city and federal agencies to evaluate conditions in Battery Park City.

Asbestos in Dust in Buildims If a substance contains more than 1% asbestos, it is considered to be an “asbestos-containing material.”

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

Environmental Monitoring Report for Lower Manhattan, October 2001 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150069Machine-extracted title
Lab report

Summary Overview of multi-agency air, water, and dust sampling efforts in Lower Manhattan to assess pollutant levels after the disaster.

Asbestos in Dust in Buildings If a substance contains more than 1% asbestos, it is considered to be an “asbestos-containing material.”

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

DEP letter on joint environmental sampling overview, Oct 2001 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151352Machine-extracted title
Lab report

Summary A DEP letter describing joint agency efforts to sample air, dust, and water in Lower Manhattan following the September 11 attacks.

Asbestos in Dust in Buildings If a substance contains more than 1% asbestos, it is considered to be an “asbestos-containing material.”

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

DEP letter on joint air dust water sampling, Oct 2001 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151350Machine-extracted title
Lab report

Summary A DEP letter describing joint agency efforts to sample air, dust, and water in Lower Manhattan following the September 11 attacks.

Asbestos in Dust in Buildings If a substance contains more than 1% asbestos, it is considered to be an “asbestos-containing material.”

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

Memorandum on asbestos wipe sampling and cancer risk estimation, December — page 15

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151649Machine-extracted title
Lab report

Summary EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.

PCM cannot distinguish asbestos fibers fi-om non-asbestos fibers.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

Memo draft for DEP Commissioner, Oct 2001 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150167Machine-extracted title
Lab report

Summary Internal memo draft addressed to the Commissioner regarding environmental compliance actions and correspondence drafts dated October 15, 2001.

Asbestos In Drinking Water EPA's standard for asbestos in drinking water is 7 million fibers per liter of water.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust, particulate, smoke

Memo on vehicle release from Ground Zero, Jan 2002 — page 9

DEP Hard Copies (68 Boxes) / DEP Box 11 / LAND FILL
NYC-WTC_000150416Machine-extracted title
Lab report

Summary Memorandum regarding the FBI releasing vehicles from Ground Zero to Fresh Kills Landfill for investigation purposes.

fi Asbestos Bulk Samples.......................................................................................... . .8 Asbestos in Air Samples - Area Samples............................

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust, silica

Lead poisoning prevention fax transmittal, undated — page 11

DEP Hard Copies (68 Boxes) / DEP Box 11 / NYC DOH
NYC-WTC_000150476Machine-extracted title
Lab report

Summary Fax cover sheet from the New York City Department of Health Lead Poisoning Prevention Program.

Asbestos Present Total % Asbestos 0J0202-S-1 202011202-01 No N.AD Location: North End-Raissd

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

DEP notice to building owners, Sep 2001 — page 3

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150160Machine-extracted title
Lab report

Summary Notice advising building owners on restarting air circulation systems and managing potential asbestos contamination in buildings south of 14th Street.

Commissioner Persons who perform air sampling must possess valid New York State Asbestos Project Air Sampling Technician Certificates.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

DEP Air Sampling Advisory for Asbestos, Sept-Oct 2001 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150091Machine-extracted title
Lab report

Summary Department of Environmental Protection advisory outlining requirements for asbestos air sampling personnel and clearance standards.

Commissioner Persons who perform air sampling must possess valid New York State Asbestos Project Air Sampling Technician Certificates.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

Analysis of very fine and coarse particulate levels at WTC — page 5

DEP Hard Copies (68 Boxes) / DEP Box 11
NYC-WTC_000151969Machine-extracted title
Unclassified

Summary Scientific report comparing air quality data from Ground Zero to other pollution events and noting high particle counts.

"Obviou-sly, our asbestos program WM overwhelmed by a qatastiophc of Ais magnitude.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

List of qualified asbestos cleanup contractors, no date specified — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / CONTRACTS CONTRACTORS - See: $ matrics etc file
NYC-WTC_000151285Machine-extracted title
Form

Summary Document listing licensed asbestos contractors meeting specific project experience and violation history criteria for WTC site work.

must have performed at least 25 asbestos projects and must have submitted asbestos project notification forms for such jobs with NYC DEP within the last two years.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

Qualified asbestos cleanup contractors list with qualification criteria — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / CONTRACTS CONTRACTORS - See: $ matrics etc file
NYC-WTC_000151205Machine-extracted title
Form

Summary Document listing licensed asbestos contractors meeting City requirements including experience, certifications, project history, and violation history for WTC cleanup work.

at least 25 asbestos projects and must have submitted asbestos project notification forms for such jobs with NYC DEP within the last two years.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

Contract requirements memo forwarding, FDNY coordination, July 2002 — page 2

DEP Hard Copies (68 Boxes) / DEP Box 11 / CONTRACTS CONTRACTORS - See: $ matrics etc file
NYC-WTC_000151284Machine-extracted title
Memo or letter

Summary Memo forwarding contract requirements documentation related to FDNY coordination for World Trade Center cleanup operations.

at least 25 asbestos projects and must have submitted asbestos project notification forms for such jobs with NYC DEP within the last two years.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

OSHA letter on asbestos monitoring data for contractors, Jun 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151548Machine-extracted title
Memo or letter

Summary OSHA letter to the EPA providing a description of asbestos monitoring data used for selecting personal protective equipment for cleanup contractors.

The air and bulk samples collected during those monitoring inspections contain no detectable levels of asbestos.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

EPA response regarding WTC residential cleaning and testing program — page 5

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151571Machine-extracted title
Memo or letter

Summary EPA Region 2 response to inquiry about the joint EPA-DEP World Trade Center residential dust cleanup and testing program funded by FEMA, noting approximately 5,300 requests…

The air and bulk samples collected during those monitoring inspections contain no detectable levels of asbestos.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust

EPA response letter regarding WTC dust program, March 2003 — page 5

DEP Hard Copies (68 Boxes) / DEP Box 11 / WTC DC TO RC LETTERS CALLEHAN WHITMAN ETC. WARD DOCTOROFF KENNY
NYC-WTC_000151559Machine-extracted title
Memo or letter

Summary EPA Region 2 responds to a congressional inquiry about the joint EPA-DEP program for testing and cleaning lower Manhattan homes after the WTC collapse.

The air and bulk samples collected during those monitoring inspections contain no detectable levels of asbestos.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust