NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
48 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗CoC/documents for asbestos-containing exterior sealant/caulking materials for DDC school task force, June 2001.
NYC-WTC_000455928–000456011OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SECTION 02082 according to the testing laboratory.
c) A minimum of five PCM and five TEM air samples will be collected inside the work area to determine final air clearance reocupancy, provided that the amount of ACM is greater than 160 square feet or 260 linear feet. All PCM and TEM results must satisfy the clearance criteria for reoccupancy.
d) When volumes greater than or equal to 1,199 liters for a 25 mm filter and/or 2,799 liters for a 37 mm filter have been collected and all the TEM samples inside the abatement area is less than 70 s/mm^ of filter, the abatement work shall be considered complete without comparing the inside samples to the outside samples.
e) When the work area passes the reoccupancy test, all controls and seals established shall be removed.
1.31 PAYMENT FOR FINAL AIR TESTING
Final Air Testing Costs:
1. All costs for the first and final air testing following clean-up when ordered by the Commissioner and as required by this Contract and Title 15, Chapter 1 of RCNY shall be borne by the Construction Manager.
2. Retesting:
Should air tests (following final clean-up) indicate a fiber count greater than 0.01 fibers per cubic centimeter (PCM) or the average number of asbestos on TEM samples is greater than 70 s/mm’ of filter, in any of the building areas, the Contractor shall re-clean the specific area. The Construction Manager will then arrange for retesting by the third party laboratory. All costs of such retesting will be at the Contractor's expense. Repeated cycles of cleaning and clearance testing will be performed until a fiber count within the Work Area is equal to or less than 0.01 fibers/cubic centimeter (PCM) and the average number of asbestos structures on TEM samples is no greater than 70s/mm- of filter is attained. The repeated cleaning will be done by the Contractor at no cost to the City. A permanent deduction equal to the cost of additional clearance air testing including all costs incurred by DDC will be made from the Contractor's payment.
1.31 PAYMENT FOR FINAL AIR TESTING
Final Air Testing Costs:
1. All costs for the first and final air testing following clean-up when ordered by the Commissioner and as required by this Contract and Title 15, Chapter 1 of RCNY shall be borne by the Construction Manager.
2. Retesting:
02082-47
CITY_21 MCI 00_014563903
NYC-WTC_000455974
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
48 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
18 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
18 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
18 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443384
State regulation reference: Part 56 of Title 12 NYCRR, asbestos compliance document.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448811
New York City Part 56 asbestos documentation, NYC-WTC.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446470
State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437549
Asbestos chain-of-custody record for NYC WTC project, including state code reference.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233286
Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451646
Asbestos Part 56 inspection reference document, NYC.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441450
Asbestos standards reference page from NY Department of Labor materials.
18 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416644
Pre-bid meeting and scope for environmental monitoring during interior cleaning.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452493
DEP pre-bid meeting notice and background for asbestos cleaning at WTC site.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435590
DEP memo outlining pre-bid meeting and asbestos monitoring for WTC renovation.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000454574
Specifications for asbestos-containing exterior sealants and caulking materials abatement.
Similar indexed content
NYC-WTC_000448332
DOL 12 NYCRR Part 56 reference and regulatory context for asbestos.
Similar indexed content
NYC-WTC_000438568
Page 1 of a chain-of-custody form referencing NY CRR Part 56 and the NYC WTC records.
Similar indexed content
NYC-WTC_000453278
Chain-of-custody for asbestos-related samples under Part 56 rules in NYC WTC context.
Similar indexed content
NYC-WTC_000450663
City asbestos regulatory document referencing NYS Part 56; file with NYC-WTC code tag.
Similar indexed content