NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Site sampling general procedures, field investigation

Machine-extracted title · confidence 44%

Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.

NYC-WTC_000455821–000455835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2. Remove laboratory precleaned sample containers from sample cooler, label container with an indelible marker, fill out Sample Information Record and Chain of Custody Form.

3. Drive the probe to the desired sampling depth.

4. Retrieve the soil probe and immediately after opening it, obtain an organic vapor measurement with a FID or PID.

5. Remove a sample aliquot from the soil probe using a disposable scoop or sterile wooden tongue depressor, place into the open sample container and replace the container cover.

6. Return the sample container to the cooler.

7. If reusable, decontaminate the sampling equipment according to the procedures described in Section 6.0.

8. Place all disposable personal protective equipment and disposable sampling equipment into a 55-gallon drum and store in a secure area (fenced, if possible).

6.9 Soil (Borehole, Split Spoon)

1. Be certain that the sample location is noted on Location Sketch (see Section 8.1).

2. Be certain that the sampling equipment (split spoon) has been decontaminated utilizing the procedures outlined in Section 6.0.

3. Remove laboratory precleaned sample containers from sample cooler, label container with an indelible marker, fill out Sample Information Record and Chain of Custody Form (see Section 8.0).

4. Drill into the soil to the desired depth and drive the split spoon sampler.

5. Retrieve the split spoon and immediately after opening the split spoon, obtain an organic vapor measurement with a PID or FID and fill out Boring Log Form (see Section 8.0).

6. Remove a sample aliquot from the split spoon using a disposable scoop or sterile wooden tongue depressor, place into the open sample container and replace the container cover.

7. Return the sample container to the cooler.

8. If reusable, decontaminate the sampling equipment according to the procedures described in Section 6.0.

9. Place all disposable personal protective equipment and disposable sampling

eD1519\A0930701.doc 6-11

CITY_21MC100_0 09947936

NYC-WTC_000455831

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455831Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →