NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
5 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Procedural table for collecting samples using Nilfisk equipment.
NYC-WTC_000321809–000321815OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
To decontaminate the sampling trains, move them to a well-ventilated area and perform the following:
1 Assemble one of the sampling trains to be used as the decontamination unit for decontaminating the nozzles, hoses, and wands. This unit must be provided with a clean polyliner and dust bag.
2 With the vacuum cleaner turned on and wearing clean surgical gloves, the nozzles, wands, and hoses are decontaminated using a bottle brush to remove any accumulated dust. Make sure to tap with your hand on the nozzle to remove any visible dirt that have accumulated on the brush. When the nozzle is considered to be clean, remove and spray with reagent grade methanol and allowed to air dry on a clean surface. The wand and hose are then cleaned with the bottle brush. Make sure to tap with your hand on the wand inlet while cleaning with the bottle brush to remove any visible dirt. Repeat this procedure to decontaminate the other nozzles, wands, and hoses.
3 Pull out the dirty dust bag from the decontamination unit and wipe clean the inside of the container with distilled water. Do the same to the other containers. Spray the inside of the containers with methanol and allow to air dry. If decontaminating in between homes, wipe cleaning the inside of the containers with distilled water is sufficient.
8.0 CALCULATIONS
The dust weight calculations for the final sieved dust fraction is performed in accordance with ASTM Method D 422. Dividing the final dust weight by the area sampled (expressed in m^) provides dust loading per square meter, in g/m^. When the analysis results are received, the loading of analyte per square meter of carpet area (ug/m") can be calculated in the same way. Analysis will also provide mg/kg concentration. If total (gross) dust loading of the sampled area needs to be calculated, the total dust weight before sieving must be obtained. The total dust weight is divided by the area sampled to obtain total dust loading per square meter.
9.0 QUALITY ASSURANCE/QUALITY CONTROL
There are no specific quality assurance activities which apply to the implementation of these procedures. However, the following general QA procedures apply;
1. All data must be documented on field data sheets or within site logbooks.
2. All instruments must be operated in accordance with operating instructions as supplied by the manufacturer, unless otherwise specified in the work plan. Equipment checkout and calibration activities must occur prior to sampling/operation and they must be documented.
10.0 DATA VALIDATION
Results of the quality control samples will be evaluated for contamination. This information will be utilized to qualify the environmental sample results accordingly with the project's data quality
5
CITY_21MC100_004068073
NYC-WTC_000321814
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
5 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
5 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437748
EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.
8 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
8 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
3 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165014
Memo from EPA to multiple NYC, state, and federal agencies coordinating WTC environmental response activities and information sharing.
3 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455821
Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.
1 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
2 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
5 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149899
Proposal for sampling and assessing building interiors in the vicinity of the World Trade Center site.
4 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
5 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205550
Document outlining mandatory pre-bid meeting and scope for interior asbestos cleaning and air monitoring at 114 Liberty Street.
3 shared non-person entities · 1 shared topics · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165900
Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000437748
EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.
Similar indexed content
NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similar indexed content
NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
Similar indexed content
NYC-WTC_000165014
Memo from EPA to multiple NYC, state, and federal agencies coordinating WTC environmental response activities and information sharing.
Similar indexed content
NYC-WTC_000455821
Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.
Similar indexed content