To decontaminate the sampling trains, move them to a well-ventilated area and perform the following:

1 Assemble one of the sampling trains to be used as the decontamination unit for decontaminating the nozzles, hoses, and wands. This unit must be provided with a clean polyliner and dust bag.

2 With the vacuum cleaner turned on and wearing clean surgical gloves, the nozzles, wands, and hoses are decontaminated using a bottle brush to remove any accumulated dust. Make sure to tap with your hand on the nozzle to remove any visible dirt that have accumulated on the brush. When the nozzle is considered to be clean, remove and spray with reagent grade methanol and allowed to air dry on a clean surface. The wand and hose are then cleaned with the bottle brush. Make sure to tap with your hand on the wand inlet while cleaning with the bottle brush to remove any visible dirt. Repeat this procedure to decontaminate the other nozzles, wands, and hoses.

3 Pull out the dirty dust bag from the decontamination unit and wipe clean the inside of the container with distilled water. Do the same to the other containers. Spray the inside of the containers with methanol and allow to air dry. If decontaminating in between homes, wipe cleaning the inside of the containers with distilled water is sufficient.

8.0 CALCULATIONS

The dust weight calculations for the final sieved dust fraction is performed in accordance with ASTM Method D 422. Dividing the final dust weight by the area sampled (expressed in m^) provides dust loading per square meter, in g/m^. When the analysis results are received, the loading of analyte per square meter of carpet area (ug/m") can be calculated in the same way. Analysis will also provide mg/kg concentration. If total (gross) dust loading of the sampled area needs to be calculated, the total dust weight before sieving must be obtained. The total dust weight is divided by the area sampled to obtain total dust loading per square meter.

9.0 QUALITY ASSURANCE/QUALITY CONTROL

There are no specific quality assurance activities which apply to the implementation of these procedures. However, the following general QA procedures apply;

1. All data must be documented on field data sheets or within site logbooks.

2. All instruments must be operated in accordance with operating instructions as supplied by the manufacturer, unless otherwise specified in the work plan. Equipment checkout and calibration activities must occur prior to sampling/operation and they must be documented.

10.0 DATA VALIDATION

Results of the quality control samples will be evaluated for contamination. This information will be utilized to qualify the environmental sample results accordingly with the project's data quality

5

CITY_21MC100_004068073

NYC-WTC_000321814

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321814Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →