A aM Cea^foei

STANDARD OPERATING PROCEDURES SOP: 2040 PAGE: 56ofll REV: 0.0 DATE: 05/17/02 COLLECTION OF INDOOR DUST SAMPLES FROM CARPETED SURFACES FOR CHEMICAL ANALYSIS USING A NILFISK GS-80 VACUUM CLEANER

1. Determine the extent of the sampling effort, the sampling methods to be employed, the amount of dust needed to reach the desired detection limit and the types and amounts of equipment and supplies needed.

2.Obtain and organize the necessary' sampling and monitoring equipment.

3. Decontaminate or pre-clean equipment, as specified in Section 7.5, and ensure that it is in working order.

4.Prepare schedule and coordinate with staff, client, regulatory agency, as appropriate.

5. Perform a general site survey prior to site cntiy in accordance with the site-specific Health and Safety Plan.

6.Measure the area to be sampled and outline it using masking tape or other appropriate methods. Draw a diagram of the rooni(s) where the sample(s) were taken, locating the sampled area(s).

7.2Cahbration Procedures

The Nilfisk GS-80 vacuum cleaner has no flow devices that require calibration prior to sampling. The sampling train shall be thoroughly inspected to ensure that it has been cleaned, properly assembled, and complete.

7.3 Field Operations

1. Prior to collecting a sample at a specific location, complete a Vacuum Sampling Work Sheet (Figure 2, Appendix A) recording all required information and sketch the area to be sampled. 9 Select a sampling area according to the data collection design outlined in the WP, QAPP or SAP. Typically, three rooms per floor are selected for sampling in each building. Each sample is collected with a dedicated sampling train that has been properly assembled, cleaned, and decontaminated to ensure sample integrity. The size/weight of each sample is dependent on the goals and objectives of the sampling event, the analyses requested, and the deshed method detection levels (MDLs). A 100-g sample is highly deshable if multiple analyses (metals, pesticides, etc.) are requested. A minimum 5- to 10-g sample is required for metal analysis only.

Using the 2-meter folding ruler or any other measuring device, outline and mark the recommended 1-square meter (m*) portion of the carpet to be sampled.

4. Begin collecting sample at one comer of the delineated sample area, moving the sampler back and forth four times over a strip running in a straight line between the defined

56

CITY_DEP_WORBY_CANNATA_SUBP_000057594

NYC-WTC_000423067

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423067Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →