NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 68 pages

WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

iSW A {wxt CfSfstei

STANDARD OPERATING PROCEDURES SOP: 2040 PAGE: 59 of 11 REV: 0.0 DATE: 05/17/02 COLLECTION OF INDOOR DUST SAMPLES FROM CARPETED SURFACES FOR CHEMICAL ANALYSIS USING A NILFISK GS-80 VACUUM CLEANER

container with deionized/distilled water. Spray the inside of the containers with methanol and allow to air dry. When decontaminating in between residential homes, cleaning the inside of the containers with deionized/distilled water is sufficient.

8.0CALCULATIONS

The dust weight calculations for the final sieved dust fraction is performed in accordance with ASTM Method D-422. Dividing the final dust weight by the area sampled (expressed in m^) provides dust loading in grams per squared meter ( g/nr ). When the analysis results are received, the loading of analyte in micrograms per square meter of carpet area (ug/m") can be calculated in the same way. The analysis provides concentrations in milligrams/kilogram (mg/kg) or micrograms/kilogram (qg/kg). If total (gross) dust loading of the sampled area needs to be calculated, the total dust weight before sieving must be obtained. The total dust weight is divided by the area sampled to obtain total dust loading in g/m^.

9.0 QUALITY ASSURANCE/QUALITY CONTROL

There are no specific quality assurance activities which apply to the implementation of these procedures. However, the following general QA procedures apply:

1. All data must be documented on field data sheets or within site logbooks.

9 All instruments must be operated in accordance with operating instructions as supplied by the manufacturer, unless otherwise specified in the work plan. Equipment checkout and calibration activities must occur prior to sampling/operation and they must be documented.

10.0 DATA VALIDATION

The information recorded during sampling will be used in conjunction with the analytical data during validation. 11.0 HEALTH AND SAFETY

When working with potential hazardous materials, follow U.S. EPA, Occupational Safety and Health (OSHA) and corporate health and safety procedures.

12.0REFERENCES

American Society For Testing And Materials. 2000. Standard Practice for Collection of Dust from Carpeted Floor for Chemical Analysis, Designation D 5438-00, Reprinted from the Annual Book of ASTM Standards, Philadelphia, PA.

59

CITY_21MC100_0 03219548

NYC-WTC_000437806

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437806Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →