WTC environmental plan, EPA review, 2005

Machine-extracted title · confidence 46%

EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.

NYC-WTC_000437748–000437815
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

outdoor WTC dust samples collected near Ground Zero, days and weeks after September 11, 2001 (Meeker, et al, 2005). From this work, we see that the WTC dust samples are dominated by gypsum, concrete, and man-made vitreous fibers (MMVF), mainly slag wool. It is on the basis of these key results that gypsum, elements of concrete, and slag wool were identified as candidates for a WTC signature. The second report discusses the analysis of EPA supplied samples taken from several indoor locations well outside of the WTC impacted area (background). These samples were taken between September of 2004 and April of 2005. Slag wool is absent from many of these background samples, but Lowers et al (2005a) state that the samples do have gypsum present, which they speculate might be due to the presence of wall board in the sampled apartments. Because of the lack of slag wool in these samples, it was concluded that these samples did not contain WTC dust. It was also concluded that perhaps slag wool is the single most critical of the three WTC dust constituents when distinguishing WTC dust from other common dusts.

Other studies also identified MMVF and gypsum as predominant components of WTC dust. In a study of air and settled dust quality in apartments in Lower Manhattan, the Agency for Toxic Substances and Disease Registry (ATSDR) and the New York City Department of Health and Mental Hygiene (NYCDOMH) found significantly more MMVF and gypsum in Lower Manhattan apartments as compared to comparison areas above 59* St (NYCDOMH/ATSDR, 2002). Meanwhile, no MMVF was found in comparison locations. They also concluded that gypsum was seen at a higher percentage in dust in Lower Manhattan samples as compared to the comparison area samples. In a comprehensive study of the composition of settled dust in the Deutsche Bank building at 130 Liberty St, R.J. Lee identified numerous hazardous contaminants that were present in the dust at levels much higher than in background office buildings, and among those substances identified in their “WTC signature” were mineral wool and gypsum (R.J. Lee, 2004).

If the WTC building collapse signature components of slag wool, gypsum, and elements of concrete arc not present, then one could conclude that WTC building collapse dust is not present. However, since these components might be present in typical New York City dust, as slag wool is a component of insulating materials in currently constructed buildings, it is possible that a test might show them to be present even though WTC dust never impacted the sampled area. A ‘screening test’ will, by its design, result in some fraction of such false positives (a location without residual WTC dust that tests positive for the above components). However, an appropriate ‘screening test’ would result in very few, if any, false negatives (a location with residual WTC dust that tests negative for the above components).

A5.2. Method Development

EPA acquired 117 dust samples during the time period of September 2004 to April 2005. Twenty- one ‘impacted’ samples were taken by the EPA at two buildings that were part of the Deutsche Bank complex located at 130 Eiberty Street and 4 Albany Street. Both buildings were uninhabited and slated for demolition. Fifty samples were taken from locations well beyond the impacted zone; these samples are considered to be ‘background’ dust. Forty-six samples were taken from locations that were possibly impacted but were a bit farther from the WTC site than the known ‘impacted’ samples. None of these forty-six samples are used in the study, but several were evaluated during the development of the analytical method. In addition, one impacted sample was obtained from the USGS. This sample was a composite sample of outdoor and indoor WTC dust collected in September of 2001. 10

CITY_21MC100_003219499

NYC-WTC_000437757

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437757Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →